System information

118 IBM and Cisco LAN Switching: Interoperability and Migration Guide
4.3.4.4 IBM 8265 VCCs
Figure 96. VCCs between the two MPCs
In Figure 96 the show signalling cross_connections port command
shows the direct connection between port 14.3 with the 8270 and port 16.3
with the Cisco 5500. A shortcut is established.
8265_C2> show signalling cross_connections port 14.3
In: slot.port vpi.vci type Out: slot.port vpi.vci type Conn Cat
-------------------------------------------------------------------------------
14.3 0.440 svc 7.1 0.123 svc p2p ubr
14.3 0.441 svc 7.1 0.124 svc p2m ubr
14.3 0.442 svc 7.1 0.125 svc p2p ubr
14.3 0.443 svc 7.1 0.126 svc p2m ubr
14.3 0.445 svc 7.1 0.128 svc p2p ubr
14.3 0.447 svc 7.1 0.130 svc p2p ubr
14.3 0.448 svc 16.3 0.169 svc p2p ubr
14.3 0.449 svc 16.3 0.170 svc p2p ubr
Total number of cross connections = 8
8265_C2> show signalling cross_connections port 16.3
In: slot.port vpi.vci type Out: slot.port vpi.vci type Conn Cat
-------------------------------------------------------------------------------
16.3 0.156 svc 7.1 0.64 svc p2p ubr
16.3 0.157 svc 7.1 0.65 svc p2m ubr
16.3 0.158 svc 7.1 0.66 svc p2p ubr
16.3 0.159 svc 7.1 0.67 svc p2m ubr
16.3 0.160 svc 7.1 0.68 svc p2p ubr
16.3 0.162 svc 7.1 0.70 svc p2p ubr
16.3 0.169 svc 14.3 0.448 svc p2p ubr
16.3 0.170 svc 14.3 0.449 svc p2p ubr
Total number of cross connections = 8