Specifications

Configuring Next-Generation High-Density PVDM3 Modules
How to Verify and Troubleshoot the Functionality of the PVDM3 Cards on Cisco Voice Gateways
11
Cisco 3900 Series, 2900 Series, and 1900 Series Integrated Services Routers Software Configuration Guide
OL-21850-01
DETAILED STEPS
Step 1 show platform hw-module-power
Use this command to display power settings of PVDM3 service modules, for example:
Router# show platform hw-module-power
PVDM:
Slot 0/1
Levels supported 0x441 : SHUT FRUGAL FULL
CURRENT level : 10 (FULL)
Previous level : 10 (FULL)
Transitions : Successful Unsuccessful
SHUT : 0 0
FRUGAL : 0 0
FULL : 0 0
Slot 0/2
Levels supported 0x441 : SHUT FRUGAL FULL
CURRENT level : 10 (FULL)
Previous level : 0 (SHUT)
Transitions : Successful Unsuccessful
SHUT : 1 0
FRUGAL : 0 1
FULL : 1 0
Slot 0/3
Levels supported 0x441 : SHUT FRUGAL FULL
CURRENT level : 10 (FULL)
Previous level : 10 (FULL)
Transitions : Successful Unsuccessful
SHUT : 0 0
FRUGAL : 0 0
FULL : 0 0
Step 2 show voice call slot/port
Note If you are connected using a Telnet session, you must enter the terminal monitor command
before the show voice call command to see console messages. This step is not necessary if you
are connected to the console port.
Use this command to display statistics for voice calls on a specific slot and port, for example:
Router# show voice call 0/1/1:23
0/1/1:23 1
vtsp level 0 state = S_CONNECT
callid 0x0011 B01 state S_TSP_CONNECT clld 4085001112 cllg 4085001112
0/1/1:23 2
vtsp level 0 state = S_CONNECT
callid 0x0012 B02 state S_TSP_CONNECT clld 4085001112 cllg 4085001112
0/1/1:23 3 - - -
0/1/1:23 4 - - -
0/1/1:23 5 - - -
0/1/1:23 6 - - -
0/1/1:23 7 - - -
0/1/1:23 8 - - -
0/1/1:23 9 - - -
0/1/1:23 10- - -
0/1/1:23 11- - -