Specifications
7
Upgrading the 1200-Watt, AC-Input Power Supplies in the Cisco 7513
OL-6324-01
Product Overview
In systems with a single power supply, and in systems with redundant power when both power supplies
are shutting down, the output fail LED lights momentarily as the system ramps down, but goes out when
the power supply has completely shut down.
The power supplies feature the following three safety interlock features:
• An on/off switch with a locking mechanism on each power supply prevents the power supply from
being removed from the chassis when the power supply switch is in the ON (|) position. When the
switch is ON, a metal tab extends into a slot in the chassis. When the switch is OFF (O), the tab is
raised and clears the slot.
shows the locking mechanism on the older AC-input power supply. shows the locking mechanism on
the new AC-input power supply.
Figure 6 On/off Switch Locking Mechanism on the Older AC-Input Power Supply
Figure 7 On/off Switch Locking Mechanism on the New AC-Input Power Supply
• A captive installation screw at the bottom of the power supply front panel provides electrical
grounding and prevents the power supply from vibrating or sliding out of the bay and dislodging
from the power connectors in the backplane. (See Figure 5.)
H3031
0
I
Power
switch
Locking device
H5266
0
I
Power
switch
Locking device