Specifications

17
Upgrading the 1200-Watt, AC-Input Power Supplies in the Cisco 7513
OL-6324-01
Removing Older Power Supplies
Figure 11 Supporting the New Power Suppl
Step 2 Use the large slotted screwdriver to tighten the captive screw that secures the power supply to the chassis
frame. (See .)
Figure 12 Location of Captive Installation Screws on the New Power Supply
Step 3 Reconnect the power cable to the power receptacle on the power supply.
Warning
This unit might have more than one power cord. To reduce the risk of electric shock, disconnect the
two power supply cords before servicing the unit. (To see translated versions of this warning, refer
to page 19.)
Note The new AC-input power supplies, which are included with this upgrade, do not ship with new AC-input
power cords.
Step 4 After the AC power cable is reconnected, reconnect the power cable at the power source but do not turn
ON power to the new power supply.
Step 5 If you are replacing both power supplies, repeat Steps 1 through 3 for the second power supply.
This completes the installation procedure for the new power supplies.
Proceed to the following section “Checking the New Power Supply Installation” to apply power and
check the installation.
H5267
0
I
AC
OK
FAN
OK
OUTPUT
FAIL
H5265
Captive screws
0
I
AC
OK
FAN
OK
OUTPUT
FAIL
0
I
AC
OK
FAN
OK
OUTPUT
FAIL
POWER
B