Specifications

2-5
Cisco 600 Series Installation and Operation Guide
78-11190-01
Chapter 2 Installation Procedures
Set Up the Hardware Environment
Configure the PC’s COM Port
For the best access to the CBOS, use your terminal emulation program (such as
HyperTerminal in Windows) to set your COM protocol to the following settings:
Baud rate: 38400 bps recommended (standard 9600 bps possible)
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
Possible Configurations
This section shows you different ways of connecting your Cisco 600 series CPE
to your telephone and computer equipment, depending on whether or not your
telephone equipment is connected to a POTS splitter.
Table 2-4 shows the configurations that will work with each Cisco 600 series CPE
model.
Back-to-Back Cabling (Cisco 633 and Cisco 673 only)
You can connect two Cisco 633s or Cisco 673s in a back-to-back configuration.
This allows one CPE to terminate the traffic of a second CPE without central
office (CO) equipment. This configuration can be used as a low-cost solution for
communicating between two locations at a distance greater than Ethernets
Table 2-4 Network Configurations
Configuration 627 633 673 675 675e 676 677 678
POTS Splitter
!!!!!!!!
EZ-DSL (Splitterless)
! !!!!!
Back-to-back
(bridging mode only)
!!