Cisco 6260 Hardware Installation Guide
OL-2365-02
Chapter 1 Product Overview
Cisco 6260 System Overview
Note The PEMs reside at the bottom of the chassis, and they are installed and accessed from the
front (see Figure 1-1 for the location of the PEM in the Cisco 6260 chassis). Each PEM is
held in place by the overhanging lip of the fan tray above it. You must remove the fan tray
before you can remove the PEM.
To turn off a Cisco 6260 that has two PEMs, you must flip the circuit breakers on both PEMs
to the OFF (0) position.
The Cisco 6260 can be ordered with only one PEM installed, and with a blank faceplate
installed in place of a second PEM.
Figure 1-23 shows a close-up of the PEM faceplate.
Figure 1-23 PEM Faceplate
Note For hardware specifications for the PEM, see the “PEM” section on page A-11.
Table 1-14 describes the PEM LED indicators and their functions.
1
PEM and fan tray status LEDs
3
Two-position circuit breaker—the positions
are Off (0) and On (1)
2
Extraction handle
4
Negative (-), positive (+), and ground DC
power terminal blocks
48430
INPUT OK
OUT FAIL
FAN TRAY 1
FANTRAY 2
1
2
3
4
Ta b l e 1- 1 4 P E M L E D s
LED State Function
Input OK Green –48V power is available to the chassis.
Out Fail Red The PEM is not distributing power to the chassis.
Fan Tray 1 Green The fans in this tray are operating normally.
Red One or more fans in this tray have failed.
Fan Tray 2 Green The fans in this tray are operating normally.
Red One or more fans in this tray have failed.