Installation guide

5-17
Cisco 6260 Hardware Installation Guide
OL-2365-01
Chapter 5 Troubleshooting
Alarms
5.6 Alarms
Tables 5-9 through 5-20 describe alarms for the Cisco 6260. In each table, the text in the Alarm column
is the text that appears in the description field of the alarm message. Alarm messages appear on the
console screen as the alarms occur; to see a list of current alarms, enter the show facility-alarm status
command.
Refer to the problem tables in this chapter for more detailed troubleshooting instructions.
Table 5-9 Chassis Alarm
Alarm Severity Description
Chassis temperature
too high
Major A temperature too high for the safe operation of the
chassis has been detected. (Temperature is measured on
the NI-2 card.)
Table 5-10 Card Slot Alarms
Alarm Severity Description
Provisioned slot is empty Major The card in this slot does not match the type configured
for this slot.
Line card not equal
to provisioning
Minor This slot is configured for a card, but no card is present.
Invalid line card for
this slot
Minor The card detected in this slot cannot operate in this slot or
is incompatible with the system configuration.
Table 5-11 Line Card Alarms
Alarm Severity Description
ATU-C port failure Minor The ATUC-DMT line card port failed.
Upstream rate below
min. rate
Minor The upstream bit rate on this port is not above the
configured minimum rate.
Downstream rate below
min. rate
Minor
The downstream bit rate on this port is not above the
configured minimum rate.
LOS, LOF, LOCD, or
LPR failure
Minor The modem reports a near-end LOS, LOF, or LOCD or a
far-end LPR (loss of power) failure. (The line must be
enabled to alarm on failures.)
Table 5-12 IOS Controller Alarms
Alarm Severity Description
Loss of active clock sync Major Loss of timing reference. The configured clock source is
not available, so the system is using its internal clock.
BITS clock failure Major BITS clock failure (LOS or AIS). The configured clock
source is not available, so the system is using its
internal clock.