© 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 5 of 8
Feature Cisco MSE 3355
Power
●
AC power supply wattage: 625W
●
AC power supply voltage: 100 to 120V at 50 to 60 Hz; 200 to 240V at 50 to 60 Hz
●
92% efficient
●
Autoswitching, hot-swappable
●
Redundant power supplies
Cooling fans Total of six fans, 3+3 redundant configuration
Environmental
●
Operating temperature:
50° to 95°F (10° to 35°C) up to 3000 ft (914.4 m)
50° to 90°F (10° to 32°C) 3000 to 7000 ft (914.4 to 2133 m)
●
Non-operating temperature:
-40° to 140°F (-40° to 60°C)
Maximum rate of change is 36°F/hr (20°C/hr)
●
v air temperature, server on:
50° to 95°F (10° to 35°C)
Altitude: 3000 ft (0 to 914.4 m), decrease system temperature by 1.0°C (1.8°F) for every 1000-foot (304.8 m )
increase in altitude
●
v air temperature, server off:
41° to 113°F (5° to 45°C)
Maximum altitude: 10,000 ft (3048 m)
●
Shipment:
-40° to 140°F (-40° to 60°C)
Maximum altitude: 10,000 ft (3048 m)
●
v humidity, server on:
20% to 80%
Maximum dewpoint: 70°F (21°C)
Maximum rate of change: 9°F/hr (5°C/hr)
●
v humidity, server off:
8% to 80%
Maximum dewpoint: 81°F (27°C)
Approvals and
compliance
●
Safety UL 60950
●
CAN/CSA -C22.2 No. 60950
●
EN60950
●
IEC 60950: EMC FCC Part 15 (CFR 47) Class A
●
ICES-003 Class A
●
EN 55022 Class A
●
CISPR22 Class A
●
AS/NZS 3548 Class A
●
VCCI Class A
●
EN 55024
●
EN 50082-1
●
Energy Star compliant