Specifications
1-18
Cisco SN 5428-2 Storage Router Software Configuration Guide
78-15471-01
Chapter 1 Before Configuring SN 5428-2 Storage Router Software
VLAN Access Overview
Figure 1-18 Multisite FCIP Configuration
VLAN Access Overview
SN 5428-2 VLAN access provides IP hosts with access to storage devices according to the VLAN to
which each host belongs.
Figure 1-19 shows a sample network that employs SN 5428-2 VLAN access. In the figure, an SN 5428-2
Gigabit Ethernet interface is connected to an IP network through an IEEE 802.1Q trunk; the SN 5428-2
Fibre Channel interfaces are connected to storage devices 1, 2, and 3. The SN 5428-2 is configured with
two SCSI routing instances named SR100 and SR200. The IP network contains two VLANs: VLAN 100
and VLAN 200. The SCSI routing instance, SR100, is configured to allow the hosts in VLAN 100 to
access storage devices 1 and 2. The SCSI routing instance, SR200, is configured to allow the hosts in
VLAN 200 to access storage device 3.
Figure 1-19 VLAN Access Overview
IP
SN 5428-2
SN 5428-2
91357
FC hosts and
storage devices
SAN 3
SN 5428-2
FC hosts and
storage devices
SAN 1
SAN 2
Cisco SN 5428-2
802.1Q trunk
Configured with two SCSI
routing instances named
SR100 and SR200
VLAN 200
VLAN 100
IP
Storage devices accessible by
VLAN 100 via SCSI routing
instance SR100
Storage device accessible by
VLAN 200 via SCSI routing
instance SR200
85732
1
2
3