Operation Manual
Cisco SPA IP Phone Field Reference
Regional Tab
Cisco Small Business SPA300 Series, SPA500 Series, and WIP310 IP Phone Administration Guide 266
A
Daylight Saving Time 
Rule 
Enter the rule for calculating daylight saving time; it 
should include the start, end, and save values. This rule 
is comprised of three fields. Each field is separated by 
; (a semicolon) as shown below. Optional values inside [ 
] (the brackets) are assumed to be 0 if they are not 
specified. Midnight is represented by 0:0:0 of the given 
date.
This is the format of the rule: Start = <start-time>; 
end=<end-time>; save = <save-time>. 
The <start-time> and <end-time> values specify the 
start and end dates and times of daylight saving time. 
Each value is in this format: <month> /<day> / 
<weekday>[/HH:[mm[:ss]]] 
The <save-time> value is the number of hours, minutes, 
and/or seconds to add to the current time during 
daylight saving time. The <save-time> value can be 
preceded by a negative (-) sign if subtraction is 
desired instead of addition. The <save-time> value is in 
this format: [/[+|-]HH:[mm[:ss]]]
The <month> value equals any value in the range 1-12 
(January-December).
The <day> value equals [+|-] any value in the range 1-
31.
If <day> is 1, it means the <weekday> on or before the 
end of the month (in other words the last occurrence of 
< weekday> in that month).
Parameter Description