Operation Manual
Configuring Regional Parameters and Supplementary Services
Scripting for Cadences, Call Progress Tones, and Ring Tones
Cisco Small Business SPA300 Series, SPA500 Series, and WIP310 IP Phone Administration Guide 174
7
Example 2: Distinctive Ring (short, short, short, long) 
60(.2/.2,.2/.2,.2/.2,1/4) 
Where:
• Number of Cadence Sections = 1 
• Cadence Section 1: Section Length = 60s 
• Number of Segments = 4 
• Segment 1: On=0.2s, Off=0.2s 
• Segment 2: On=0.2s, Off=0.2s 
• Segment 3: On=0.2s, Off=0.2s 
• Segment 4: On=1.0s, Off=4.0s 
• Total Ring Length=60s
Tone Script
A ToneScript is a mini-script that specifies the frequency, level, and cadence of a 
call progress tone. It can contain up to 127 characters. Syntax: 
FreqScript;Z1[;Z2]
Section Zi is similar to the Si section in a CadScript except that each on/off 
segment is followed by a frequency parameter: Zi = Di(oni,1/offi,1/
fi,1[,oni,2/offi,2/fi,2 [,oni,3/offi,3/fi,3 [,oni,4/offi,4/
fi,4 [,oni,5/offi,5/fi,5 [,oni,6/offi,6/fi,6]]]]])
where fi,j = n1[+n2]+n3[+n4[+n5[+n6]]]]] 1< nk < 6 indicates which 
of the frequency components given in the FreqScript are used in that segment; if 
more than one frequency component is used in a segment, the components are 
summed together. 
Example: Dial Tone 
350@-19,440@-19;10(*/0/1+2) 
• Number of Frequencies = 2 
• Frequency 1 = 350 Hz at –19 dBm 
• Frequency 2 = 440 Hz at –19 dBm 