Installation guide

4-74 Cisco 4000 Series Installation Guide
Network Connection Considerations
Following are the available E1-G.703/G.704 module options:
Four port E1-G.703/G.704, 120-ohm, balanced
Four port E1-G.703/G.704, 75-ohm, unbalanced
E1 cable, TWINAX, 120-ohm, balanced, 5 meters
E1 cable, DB-15, 120-ohm, balanced, 5 meters
E1 cable, BNC, 75-ohm, unbalanced, 5 meters
G.703/G.704 Maximum Cable Lengths
Unbalanced G.703 interfaces allow for a longer maximum cable length than those specified
for balanced circuits. Table 4-6 lists the maximum cable lengths for each E1-G.703/G.704
cable type by the connector used at the network end (away from the network processor
module).
Table 4-6 E1-G.703/G.704 Maximum Cable Lengths
G.703/G.704 Cable Connections
Figure 4-26, Figure 4-27, and Figure 4-28 show the unbalanced and balanced cables used
for connection between the E1-G.703/G.704 port and your network. The port adapter end
of each cable has a DB-15 connector.
Connection Type BNC Twinax
Balanced 300 m
Unbalanced 600 m