Installation guide

Cabling Specifications A-83
Ethernet Cable Pinouts
Figure A-20 MII Connection (Female)
Table A-32 lists the MII connector pinouts and signals. MII cables are available
commercially.
1. Any pins not indicated are not used.
2. Tx_CLK and Rx_CLK are generated by the external transceiver.
Table A-32 MII Connector Pinouts and Signals
Pin
1
In Out In/Out Description
14–17 Yes Transmit Data (TxD)
12 Yes Transmit Clock (Tx_CLK)
2
11 Yes Transmit Error (Tx_ER)
13 Yes Transmit Enable (Tx_EN)
3 Yes MII Data Clock (MDC)
4–7 Yes Receive Data (RxD)
9 Yes Receive Clock (Rx_CLK)
10 Yes Receive Error (Rx_ER)
8 Yes Receive Data Valid (Rx_DV)
18 Yes Collision (COL)
19 Yes Carrier Sense (CRS)
2 Yes MII Data Input/Output (MDIO)
22–39 Common (ground)
1, 20, 21, 40 +5.0 volts (V)
Jackscrew Pin 21
Pin 1
H7057