Installation guide

Chapter 3 Switch Installation
Preparing for Installation
3-6
Catalyst 3750 Switch Hardware Installation Guide
78-15136-02
Installation Guidelines
When determining where to place the switch, be sure to observe these
requirements:
For 10/100 and 10/100/1000 ports, cable lengths from the switch to connected
devices are up to 328 feet (100 meters).
Copper 1000BASE-T SFP modules use standard four twisted-pair, Category
5 cable at lengths up to 328 feet (100 meters).
Table 3-1 lists the cable specifications for 1000BASE-SX and
1000BASE-LX fiber-optic SFP connections. Each port must match the
wave-length specifications on the other end of the cable, and the cable must
not exceed the stipulated cable length for reliable communications.
Operating environment is within the ranges listed in Appendix A, Technical
Specifications.
Clearance to front and rear panels is such that
Front-panel indicators can be easily read.
Access to ports is sufficient for unrestricted cabling.
Table 3-1 Fiber-Optic SFP Module Port Cabling Specifications
SFP Module
Wavelength
(nanometers) Fiber Type
Core Size
(micron)
Modal
Bandwidth
(MHz/km) Cable Distance
1000BASE-SX 850 MMF 62.5
62.5
50.0
50.0
160
200
400
500
722 feet (220 m)
902 feet (275 m)
1640 feet (500 m)
1804 feet (550 m)
1000BASE-LX/LH 1300 MMF
1
SMF
1. A mode-conditioning patch cord is required. Using an ordinary patch cord with MMF, 1000BASE-LX/LH SFP modules,
and a short link distance can cause transceiver saturation, resulting in an elevated bit error rate (BER). When using the
LX/LH SFP module with 62.5-micron diameter MMF, you must also install a mode-conditioning patch cord between the
SFP module and the MMF cable on both the sending and receiving ends of the link. The mode-conditioning patch cord is
required for link distances greater than 984 feet (300 m).
62.5
50.0
50.0
9/10
500
400
500
1804 feet (550 m)
1804 feet (550 m)
1804 feet (550 m)
32,810 feet (10 km)