UFAST_MCAST_SW Messages
Error Message UDLD-6-UDLD_PORT_RESET: UDLD reset interface [chars].
Explanation
The UDLD Protocol detected a unidirectional connection between neighbors. Reset the
port that was disabled by UDLD by using the udld reset privileged EXEC command or through a
hardware action such as a link-state change. [chars] is the interface.
Recommended Action Find out more about the error by using the show tech-support privileged EXEC
command and by copying the error message exactly as it appears on the console or system log and
entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported problems. For
more information about these online tools and about contacting Cisco, see the “Error Message
Traceback Reports” section on page 1-2.
UFAST_MCAST_SW Messages
This section contains UplinkFast (UFAST) packet transmission messages.
Error Message UFAST_MCAST_SW-3-PROC_START_ERROR: No process available for
transmitting UplinkFast packets.
Explanation UplinkFast packets will not be sent because the process could not be created.
Recommended Action UplinkFast does not work unless you reload the switch software. If this
problem persists even after reload, find out more about the error by using the show tech-support
privileged EXEC command and by copying the error message exactly as it appears on the console or
system log and entering it in the Output Interpreter tool. Use the Bug Toolkit to look for similar reported
problems. For more information about these online tools and about contacting Cisco, see the “Error
Message Traceback Reports” section on page 1-2.
Error Message UFAST_MCAST_SW-4-MEM_NOT_AVAILABLE: No memory is available for
transmitting UplinkFast packets on Vlan [dec].
Explanation
UplinkFast packets will not be sent on a VLAN due to memory limitations. [dec] is the
VLAN ID.
Recommended Action Reduce other system activity to ease memory demands.
VQPCLIENT Messages
This section contains VLAN Query Protocol (VQP) client messages.
Error Message VQPCLIENT-2-CHUNKFAIL: Could not allocate memory for VQP.
Explanation An error occurred when the system tried to allocate memory for the VQP client.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
tech-support user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, open a case