Specifications
14-17
Catalyst 2950 and Catalyst 2955 Switch Software Configuration Guide
78-11380-07
Chapter 14 Configuring Optional Spanning-Tree Features
Configuring Optional Spanning-Tree Features
Beginning in privileged EXEC mode, follow these steps to globally enable the BPDU filtering feature:
To disable BPDU filtering, use the no spanning-tree portfast bpdufilter default global configuration
command.
You can override the setting of the no spanning-tree portfast bpdufilter default global configuration
command by using the spanning-tree bpdufilter enable interface configuration command.
Enabling UplinkFast for Use with Redundant Links
UplinkFast cannot be enabled on VLANs that have been configured for switch priority. To enable
UplinkFast on a VLAN with switch priority configured, first restore the switch priority on the VLAN to
the default value by using the no spanning-tree vlan vlan-id priority global configuration command.
Note When you enable UplinkFast, it affects all VLANs on the switch. You cannot configure UplinkFast on
an individual VLAN.
The UplinkFast feature is supported only when the switch is running PVST. It is not supported when the
switch is running PVRST.
Beginning in privileged EXEC mode, follow these steps to enable UplinkFast:
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
spanning-tree portfast bpdufilter default Globally enable BPDU filtering.
By default, BPDU filtering is disabled.
Step 3
interface interface-id Enter interface configuration mode, and specify the interface
connected to an end station.
Step 4
spanning-tree portfast Enable the Port Fast feature.
Step 5
end Return to privileged EXEC mode.
Step 6
show running-config Verify your entries.
Step 7
copy running-config startup-config (Optional) Save your entries in the configuration file.
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
spanning-tree uplinkfast [max-update-rate
pkts-per-second]
Enable UplinkFast.
(Optional) For pkts-per-second, the range is 0 to 32000 packets per
second; the default is 150.
If you set the rate to 0, station-learning frames are not generated,
and the spanning-tree topology converges more slowly after a loss
of connectivity.
Step 3
end Return to privileged EXEC mode.
Step 4
show spanning-tree summary Verify your entries.
Step 5
copy running-config startup-config (Optional) Save your entries in the configuration file.