Specifications
A-21
Catalyst 2950 and Catalyst 2955 Switch Command Reference
78-15304-01
Appendix A Catalyst 2955-Specific Alarm Commands
test relay
test relay
Use the test relay privileged EXEC command to turn on or off the relay circuitry.
test relay {major | minor} {on| off}
Caution Using the test command alters the state (on or off) of a relay. Previous states are not saved.
Command Modes Privileged EXEC
Command History
Usage Guidelines You can use the test relay privileged EXEC command to check relay circuitry connections to the alert
devices. The command provides a way to test alarm scanners without having to create an alarm
condition.
Examples This example shows how to turn on the major relay circuitry.
Switch# test relay major on
Related Commands
Release Modification
12.1(12c)EA1 This command was first introduced.
Command Description
show alarm profile Displays all alarm profiles or a specified alarm profile and lists the
interfaces to which each profile is attached.
show alarm settings Displays environmental alarm settings and options.
show facility-alarm
relay
Displays alarm relays generated on the switch.