show facility-alarm status
show facility-alarm status
Use the show facility-alarm status user EXEC command to display all generated alarms in the switch.
show facility-alarm status [critical | info | major | minor] [ | {begin | exclude | include}
expression]
Syntax Description
Command Modes User EXEC
Command History
Usage Guidelines Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
are not displayed, but the lines that contain Output are displayed.
Examples This example displays alarm information for the switch.
Switch> show facility-alarm status
Source Severity Description Relay Time
FastEthernet0/3 MINOR 2 Port Not Forwarding NONE Mar 01
1993 00:02:22
Related Commands
critical (Optional) Display only critical facility alarms.
info (Optional) Display all facility alarms.
major (Optional) Display major facility alarms and higher.
minor (Optional) Display major facility alarms and higher.
| begin (Optional) Display begins with the line that matches the expression.
| exclude (Optional) Display excludes lines that match the expression.
| include (Optional) Display includes lines that match the specified expression.
expression Expression in the output to use as a reference point.
Release Modification
12.1(12c)EA1 This command was first introduced.
Command Description
alarm facility
power-supply
Sets power supply alarm options.
alarm facility
temperature
Sets temperature alarm options.
alarm profile (global
configuration)
Creates alarm profiles with alarm IDs and alarm options to be attached to
interfaces.
show facility-alarm
relay
Displays alarm relays generated on the switch.