Specifications
A-18
Catalyst 2950 and Catalyst 2955 Switch Command Reference
78-15304-01
Appendix A Catalyst 2955-Specific Alarm Commands
show facility-alarm relay
show facility-alarm relay
Use the show facility-alarm relay user EXEC command to display facility alarms associated with the
indicated relay circuitry.
show facility-alarm relay {major | minor} [ | {begin | exclude | include} expression]
Syntax Description
Command Modes User EXEC
Command History
Usage Guidelines Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output
are not displayed, but the lines that contain Output are displayed.
Examples This example displays alarm information for the minor relays.
Switch> show facility-alarm relay minor
Source Description Relay Time
Switch 1 Temp above secondary thresh MIN Mar 01 1993 00:0 1:17
Related Commands
major Display alarms associated with major relay.
minor Display alarms associated with minor relay.
| begin (Optional) Display begins with the line that matches the expression.
| exclude (Optional) Display excludes lines that match the expression.
| include (Optional) Display includes lines that match the specified expression.
expression Expression in the output to use as a reference point.
Release Modification
12.1(12c)EA1 This command was first introduced.
Command Description
alarm facility
power-supply
Sets power supply alarm options.
alarm facility
temperature
Sets temperature alarm options.
alarm profile (global
configuration)
Creates alarm profiles with alarm IDs and alarm options to be attached to
interfaces.
show facility-alarm
status
Display alarms generated on the switch.