Specifications

A-5
Catalyst 2950 and Catalyst 2955 Switch Command Reference
78-15304-01
Appendix A Catalyst 2955-Specific Alarm Commands
alarm facility temperature
Examples This example sets the secondary temperature with a high threshold value of 45
0
C with alarms and traps
sent to the minor relay circuitry, syslog, and an SNMP server.
Switch(config) # alarm facility temperature secondary 45
Switch(config) # alarm facility temperature secondary relay minor
Switch(config) # alarm facility temperature secondary syslog
Switch(config) # alarm facility temperature secondary notifies
This example disables the secondary temperature alarm.
Switch(config) # no alarm facility temperature secondary 45
This example sets the primary temperature alarm with alarms and traps to go to syslog and the major
relay circuitry.
Switch(config) # alarm facility temperature primary syslog
Switch(config) # alarm facility temperature primary relay major
Related Commands Command Description
show alarm settings Displays environmental alarm settings and options.
snmp-server enable
traps
Enables the switch to send Simple Network Management Protocol (SNMP)
notification for various trap types to the network management system
(NMS).