Installation guide

3-5
Catalyst 2950 Desktop Switch Hardware Installation Guide
78-11157-03
Chapter 3 Troubleshooting
Diagnosing Problems
System LED is amber Internal fan fault detected. Check if the fan has failed
by using the show env fan
privileged EXEC command.
If the fan has failed, call
Cisco Systems.
Nonfatal or fatal POST error
detected.
Use the show post
privileged EXEC command
to see which POST test
failed.
Switch placed in
error-disabled state after
GBIC module is inserted
Bad or non-Cisco-approved GBIC
module.
Remove GBIC module from the
switch, and replace it with a
Cisco-approved module. Use the
errdisable recovery cause
gbic-invalid global
configuration command to
verify port status, and enter a
time interval to recover from the
error-disable state.
Refer to the switch software
configuration guide for
information about the
errdisable recovery command.
Table 3-1 Common Problems and Solutions (continued)
Symptom Possible Cause Resolution