Catalyst 2950 Desktop Switch Hardware Installation Guide July 2002 Corporate Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
CCIP, the Cisco Powered Network mark, the Cisco Systems Verified logo, Cisco Unity, Follow Me Browsing, FormShare, Internet Quotient, iQ Breakthrough, iQ Expertise, iQ FastTrack, the iQ Logo, iQ Net Readiness Scorecard, Networking Academy, ScriptShare, SMARTnet, TransPath, and Voice LAN are trademarks of Cisco Systems, Inc.
C ON T E NT S Cisco Limited Lifetime Hardware Warranty Terms xi Preface xv Audience xv Purpose xv Organization xvi Conventions xvi Related Publications xix Obtaining Documentation xx World Wide Web xx Documentation CD-ROM xxi Ordering Documentation xxi Documentation Feedback xxi Obtaining Technical Assistance xxii Cisco.
Contents GBIC Module Ports 1-8 LEDs 1-9 System LED 1-12 RPS LED 1-13 Port Mode and Port Status LEDs 1-13 Rear-Panel Description 1-20 Power Connectors 1-22 Internal Power Supply Connector 1-22 DC Power Connector 1-22 Cisco RPS Connector 1-23 Console Port 1-23 Management Options 1-23 CHAPTER 2 Installation 2-1 Preparing for Installation 2-2 Warnings 2-2 EMC Regulatory Statements 2-4 U.S.A.
Contents Installing the GBIC Modules 2-20 Powering On the Switch 2-22 Connecting to DC Power 2-23 Preparing for Installation 2-23 Grounding the Switch 2-24 Wiring the DC-Input Power Source 2-26 Running POST 2-32 Connecting to 10/100 and 10/100/1000 Ports 2-33 Connecting to 100BASE-FX and 1000BASE-SX Ports 2-37 Connecting to GBIC Module Ports 2-38 Connecting to 1000BASE-X GBIC Module Ports 2-39 Connecting to 1000BASE-T GBIC Module Ports 2-41 Connecting to GigaStack GBIC Module Ports 2-42 Connecting a PC or
Contents 1000BASE-X GBIC Module Ports B-5 1000BASE-T GBIC Module Ports B-5 GigaStack GBIC Module Ports B-6 Console Port B-6 Cable and Adapter Specifications B-7 Two Twisted-Pair Cable Pinouts B-7 Four Twisted-Pair Cable Pinouts for 10/100 Ports B-8 Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports B-9 Cable and Adapter Pinouts B-10 Connecting to a PC B-10 Connecting to a Terminal B-11 Identifying a Rollover Cable B-12 APPENDIX C Translated Safety Warnings C-1 Attaching the Cisco RPS (model PWR300-AC-
Contents Laser Beam Exposure Warning C-22 Catalyst 2950G-24-EI-DC Service Requirement C-23 Restricted Area Equipment Installation C-24 Ethernet Cable Shielding in Offices C-25 DC Power Disconnection Warning C-26 Exposed DC Power Wire Warning C-29 Service Personnel Warning C-30 INDEX Catalyst 2950 Desktop Switch Hardware Installation Guide 78-11157-03 ix
Contents Catalyst 2950 Desktop Switch Hardware Installation Guide x 78-11157-03
Cisco Limited Lifetime Hardware Warranty Terms There are special terms applicable to your hardware warranty as well as services you may use during the warranty period. Your formal Warranty Statement, including the warranty applicable to Cisco software, appears in the CD which accompanies your Cisco Product. Follow these steps to access and download the Cisco Information Packet and your warranty document from the CD or from Cisco.com. 1. Launch your browser and go to the following URL: http://www.cisco.
Cisco Limited Lifetime Hardware Warranty Terms Note 3. You must have Adobe Acrobat Reader in order to view and print a PDF file. If you do not have the viewer, click the Get Acrobat Reader icon at the bottom of the page to go to the Adobe.com website and download the reader. To view translated and/or localized warranty information about your product, follow these steps: a. Enter the following part number in the Warranty Document Number field: 78-6310-02C0 b. Select the language to view the document. c.
Cisco Limited Lifetime Hardware Warranty Terms Complete the information below and keep for ready reference.
Cisco Limited Lifetime Hardware Warranty Terms Catalyst 2950 Desktop Switch Hardware Installation Guide xiv 78-11157-03
Preface Audience This guide is for the networking or computer technician responsible for installing a Catalyst 2950 switch, hereafter referred to as the switch. We assume that you are familiar with the concepts and terminology of Ethernet and local area networking. Purpose This guide describes the hardware features of Catalyst 2950 switch. It describes the physical and performance characteristics of the switch, explains how to install a switch, and provides troubleshooting information.
Preface Organization Organization This guide is organized into these chapters: Chapter 1, “Overview,” describes the switch ports, the standards that they support, and the LEDs. Chapter 2, “Installation,” contains the procedures for installing a switch on a rack, table, shelf, or desk. It also describes how to install Gigabit Interface Converter (GBIC) modules, how to power the switch, and how to make port connections.
Preface Conventions Warning This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. (To see translations of the warnings that appear in this publication, refer to the Appendix C, “Translated Safety Warnings.”) Waarschuwing Dit waarschuwingssymbool betekent gevaar.
Preface Conventions Warnung Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu einer Körperverletzung führen könnte. Bevor Sie mit der Arbeit an irgendeinem Gerät beginnen, seien Sie sich der mit elektrischen Stromkreisen verbundenen Gefahren und der Standardpraktiken zur Vermeidung von Unfällen bewußt. (Übersetzungen der in dieser Veröffentlichung enthaltenen Warnhinweise finden Sie im Anhang mit dem Titel C “Translated Safety Warnings” (Übersetzung der Warnhinweise).
Preface Related Publications ¡Advertencia! Varning! Este símbolo de aviso significa peligro. Existe riesgo para su integridad física. Antes de manipular cualquier equipo, considerar los riesgos que entraña la corriente eléctrica y familiarizarse con los procedimientos estándar de prevención de accidentes. (Para ver traducciones de las advertencias que aparecen en esta publicación, consultar el apéndice titulado C “Translated Safety Warnings.”) Denna varningssymbol signalerar fara.
Preface Obtaining Documentation • Catalyst 2950 Desktop Switch Software Configuration Guide (order number DOC-7811380=) • Catalyst 2950 Desktop Switch Command Reference (order number DOC-7811381=) • Catalyst 2950 Desktop Switch System Message Guide (order number DOC-7814233=) • Catalyst 2950 Desktop Switch Hardware Installation Guide (order number DOC-7811157=) • Catalyst GigaStack Gigabit Interface Converter Hardware Installation Guide (order number DOC-786460=) • Cluster Management Suite (CMS)
Preface Obtaining Documentation Documentation CD-ROM Cisco documentation and additional literature are available in a Cisco Documentation CD-ROM package, which is shipped with your product. The Documentation CD-ROM is updated monthly and may be more current than printed documentation. The CD-ROM package is available as a single unit or through an annual subscription.
Preface Obtaining Technical Assistance To submit your comments by mail, use the response card behind the front cover of your document, or write to the following address: Cisco Systems Attn: Document Resource Connection 170 West Tasman Drive San Jose, CA 95134-9883 We appreciate your comments. Obtaining Technical Assistance Cisco provides Cisco.com as a starting point for all technical assistance.
Preface Obtaining Technical Assistance Technical Assistance Center The Cisco TAC is available to all customers who need technical assistance with a Cisco product, technology, or solution. Two types of support are available through the Cisco TAC: the Cisco TAC Web Site and the Cisco TAC Escalation Center.
Preface Obtaining Technical Assistance If you cannot resolve your technical issues by using the Cisco TAC website, and you are a Cisco.com registered user, you can open a case online by using the TAC Case Open tool at the following URL: http://www.cisco.com/tac/caseopen If you have Internet access, it is recommended that you open P3 and P4 cases through the Cisco TAC website.
C H A P T E R 1 Overview This chapter provides information about these topics: • Features, page 1-1 • Front-Panel Description, page 1-3 • Rear-Panel Description, page 1-20 • Management Options, page 1-23 Features The Catalyst 2950 switches are stackable Ethernet switches to which you can connect workstations and other network devices, such as servers, routers, and other switches.
Chapter 1 Overview Features – Catalyst 2950G-12-EI—12 10/100 Ethernet ports and 2 Gigabit Interface Converter (GBIC) module slots – Catalyst 2950G-24-EI—24 10/100 Ethernet ports and 2 GBIC module slots – Catalyst 2950G-24-EI-DC—24 10/100 Ethernet ports and 2 GBIC module slots with direct current (DC)-input power – Catalyst 2950G-48-EI—48 10/100 Ethernet ports and 2 GBIC module slots – Catalyst 2950SX-24 switch—24 10/100 Ethernet ports and 2 1000BASE-SX ports – Catalyst 2950T-24 switch—24 10/100 Ethe
Chapter 1 Overview Front-Panel Description Power redundancy • – Connection for an optional Cisco RPS 300 Redundant Power System (RPS) that uses alternating current (AC) input and supplies DC output to the switch Front-Panel Description The switch front panel contains the ports, the LEDs, and the Mode button. Figure 1-1 to Figure 1-9 show the switches.
Chapter 1 Overview Front-Panel Description SYST 1x RPS STAT UTIL DUPLX 2x Catalyst 2950C-24 Switch 3x 4x 5x 6x SPEED 7x 8x 9x MODE 10x 11x 10BASE-T / 100BASE -TX 12x 13x 14x 15x 16x 17x 18x 19x 20x 21x Catalyst 295 0 SERIE S 22x 23x 100BASE -FX 24x 25 45570 Figure 1-3 26 10/100 ports 100BASE-FX ports Figure 1-4 1 SYST 2 3 4 1X 5 Catalyst 2950G-12-EI Switch 6 RPS STAT UTIL DUPLX 7 8 9 10 11 12 SPEED 11X 2X 12X 1 Catalyst 295 0 SERIE S 60978 MO
Chapter 1 Overview Front-Panel Description 1 SYST 2 3 4 Catalyst 2950G-24-EI-DC Switch 5 1X 6 7 RPS STAT UTIL DUPLX 8 9 10 11 12 SPEED 13 11X 14 15 16 13X 17 18 MODE 19 20 21 2X 22 23 60977 Figure 1-6 24 23X 12X Catalyst 295 0 SERIE 14X 1 S 24X 2 10/100 ports GBIC module slots 1 SYST 2 3 4 1X RPS 5 Catalyst 2950G-48-EI Switch 6 7 STAT 8 9 10 11 UTIL 12 13 14 15 16 DUPLX 17 SPEED MODE 15X 17X 16X 18X 18 19 20 21 22 23 24 2X 25
Chapter 1 Overview Front-Panel Description SYST RPS STAT UTIL DUPLX SPEED 1x 2x Catalyst 2950T-24 Switch 3x 4x 5x 6x 7x MODE 8x 9x 10x 11x 10Base-T / 100BaseTX 12x 13x 14x 15x 16x 17x 18x 19x 20x 21x Catalyst 295 0 SERIE S 22x 23x 24x 10/100/1 00Base-T 1 47337 Figure 1-9 2 10/100 ports 10/100/1000 ports 10/100 Ports The 10/100 ports use RJ-45 connectors and twisted-pair cabling.
Chapter 1 Overview Front-Panel Description When set for autonegotiation, a port senses the speed and duplex settings of the attached device and advertises its own capabilities. If the attached device supports autonegotiation, the port negotiates the best connection (that is, the fastest line speed that both devices support and full-duplex transmission, if the attached device supports it) and configures itself accordingly.
Chapter 1 Overview Front-Panel Description 100BASE-FX and 1000BASE-SX Ports The 100BASE-FX and 1000BASE-SX ports both use 50/125- or 62.5/125-micron multimode fiber-optic cabling. The 100BASE-FX ports operate only at 100 Mbps in full-duplex mode, and the 1000BASE-SX ports operate only at 1000 Mbps in full-duplex mode. In full-duplex mode, the cable length from a switch to an attached device cannot exceed 1804 feet (550 meters).
Chapter 1 Overview Front-Panel Description • 1000BASE-T GBIC module for copper connections that cannot exceed 328 feet (100 meter). • CWDM GBIC module for single-mode fiber-optic connections that cannot exceed 393,719 feet (120 kilometer). • GigaStack GBIC module for creating a 1-Gbps stack configuration of up to nine supported switches.
Chapter 1 Overview Front-Panel Description Figure 1-10 LEDs on Catalyst 2950-12, 2950-24, 2950C-24, 2950SX-24, and 2950T-24 Switches RPS LED Port status LEDs System LED SYST RPS Port mode LEDs STAT 1x 2x 3x UTIL D UPLX SP EED 4x 5x 6x Mode button 52918 MODE Catalyst 2950 Desktop Switch Hardware Installation Guide 1-10 78-11157-03
Chapter 1 Overview Front-Panel Description Figure 1-11 LEDs on Catalyst 2950G-12-EI, 2950G-24-EI, and 2950G-24-EI-DC Switches RPS LED Port status LEDs System LED 1 1X RPS Port mode LEDs STAT UTIL D UPLX S PEED MODE 2 3 4 5 6 7 8 9 10 11 12 11X 2X 12X Mode button 65395 SYST Catalyst 2950 Desktop Switch Hardware Installation Guide 78-11157-03 1-11
Chapter 1 Overview Front-Panel Description Figure 1-12 LEDs on Catalyst 2950G-48-EI Switches Port status LEDs System LED 1 SYST RPS LED 1X RPS 2 3 4 5 6 7 8 STAT UTIL DUPLX Port mode LEDs 9 10 11 12 13 14 15 16 SPEED 15X MODE 16X Mode button 65508 2X System LED The system LED shows whether the system is receiving power and functioning properly. Table 1-2 lists the LED colors and meanings. Table 1-2 System LED Color System Status Off System is not powered up.
Chapter 1 Overview Front-Panel Description RPS LED The RPS LED shows the RPS status. Table 1-3 lists the LED colors and meanings. Table 1-3 RPS LED Color RPS Status Off RPS is off or is not installed. Solid green RPS is connected and ready to provide back-up power. Flashing green RPS is connected but is unavailable because it is providing power to another device (redundancy has been allocated to a neighboring device). Solid amber RPS is in standby mode or in a fault condition.
Chapter 1 Overview Front-Panel Description Table 1-4 Port Mode LEDs Mode LED Port Mode Description STAT Port status The port status. This is the default mode. UTIL Switch utilization The current bandwidth in use by the switch. DUPLX Port duplex mode The port duplex mode: half duplex or full duplex. SPEED Port speed The port operating speed: 10 or 100 Mbps for 10/100 ports and 10, 100, or 1000 Mbps for 10/100/1000 ports.
Chapter 1 Overview Front-Panel Description Figure 1-14 Changing the Port Mode on Catalyst 2950G-12-EI, 2950G-24-EI, and 2950G-24-EI-DC Switches 1 1X RPS STAT 2 3 4 5 6 7 8 9 10 11 12 UTIL D UPLX S PEED MODE 11X 2X 12X Mode button 65393 SYST Catalyst 2950 Desktop Switch Hardware Installation Guide 78-11157-03 1-15
Chapter 1 Overview Front-Panel Description Figure 1-15 Changing the Port Mode on Catalyst 2950G-48-EI Switches 1 SYST RPS 2 3 4 1X STAT UTIL DUPLX 5 6 7 8 9 10 11 12 13 14 15 16 SPEED 15X 2X Mode button 16X 65509 MODE Catalyst 2950 Desktop Switch Hardware Installation Guide 1-16 78-11157-03
Chapter 1 Overview Front-Panel Description When you change the port mode, the meanings of the port LED colors change. Table 1-5 explains how to interpret these colors. Table 1-5 Meaning of Port LED Colors in Different Modes Port Mode Color Meaning STAT (port status) Off No link. Solid green Link present. Flashing green Activity. Port is transmitting or receiving data. Alternating green-amber Link fault.
Chapter 1 Overview Front-Panel Description Table 1-5 Meaning of Port LED Colors in Different Modes (continued) Port Mode Color SPEED (speed) 10/100 ports Meaning Off Port is operating at 10 Mbps. Green Port is operating at 100 Mbps. 10/100/1000 ports Off Port is operating at 10 Mbps. Green Port is operating at 100 Mbps. Flashing green Port is operating at 1000 Mbps. 1000BASE-X GBIC module ports Off Port is not operating. Green Port is operating at 1000 Mbps.
Chapter 1 Overview Front-Panel Description If all LEDs on Catalyst 2950G-48-EI switches are green (no amber showing), the switch is using 50 percent or more of the total bandwidth. If the LED for GBIC module slot 2 is off, the switch is using more than 25 but less than 50 percent of the total bandwidth. If LEDs for both GBIC module slots are off, the switch is using less than 25 percent of the total bandwidth, and so on. (See Figure 1-19.
Chapter 1 Overview Rear-Panel Description Figure 1-18 Bandwidth Utilization on Catalyst 2950G-24-EI and 2950G-24-EI-DC Switches 2 3 4 5 6 7 8 9 10 11 12 13 14 11X 15 16 17 18 19 20 21 22 Catalyst 2950 23 24 13X 15X 1 STAT 65396 1 1X SYST 2 RPS UTIL DUPLX SPEED 2X 12X 14X 16X MODE < 25% + 25% – 49% + 50% + Figure 1-19 Bandwidth Utilization on Catalyst 2950G-48-EI Switches Catalyst 2950 1 2 3 24 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
Chapter 1 Overview Rear-Panel Description Figure 1-20 Catalyst 2950 Switch Rear Panel DC INPUT FO POWE R REMOTE SPECIF R SUPPLY IED IN +12V @4MANUAL. .5A 45585 RATING 100-127V~ @ 1A 200-240V~ @0.5A 50-60Hz CONSOLE AC power connector RPS connector Fan RJ-45 console port Figure 1-21 Catalyst 2950G-48-EI Switch Rear Panel DC INPUT FO POWE R REMOTE SPECIF R SUPPLY IED IN +12V @4MANUAL. .5A 65511 RATING 100-127V~ @ 1A 200-240V~ @0.
Chapter 1 Overview Rear-Panel Description 36 - 72V 1 - 0.5A DC INPUT FO POWE R REMOTE SPECIF R SUPPLY IED IN +12V @4MANUAL. .5A A B CONSOLE DC power connector RPS connector Fan 65291 Figure 1-22 Catalyst 2950G-24-EI-DC Switch Rear Panel RJ-45 DC console ground port lug Power Connectors You can provide power to a switch by using the AC internal power supply, the DC-input power source, or the Cisco RPS.
Chapter 1 Overview Management Options Cisco RPS Connector The RPS is a 300W redundant power system that can support six external network devices and provides DC power to one failed device at a time. It automatically senses when the internal power supply of a connected device fails and provides power to that device, preventing loss of network traffic. Warning Attach only the Cisco RPS 300 (model PWR300-AC-RPS-N1) to the RPS receptacle.
Chapter 1 Overview Management Options • IOS command-line interface (CLI) You can manage switches by using command-line entries. To access the CLI, connect a PC or terminal directly to the console port on the switch rear panel. If the switch is attached to your network, you can use a Telnet connection to manage the switch from a remote location. For more information, refer to the switch command reference.
C H A P T E R 2 Installation This chapter describes how to install your switch, interpret the power-on self-test (POST), and connect the switch to other devices.
Chapter 2 Installation Preparing for Installation Preparing for Installation This section provides information about these topics: • Warnings, page 2-2 • EMC Regulatory Statements, page 2-4 • Installation Guidelines, page 2-6 • Verifying Package Contents, page 2-7 Warnings These warnings are translated into several languages in Appendix C, “Translated Safety Warnings.” Warning This equipment is to be installed and maintained by service personnel only as defined by AS/NZS 3260 Clause 1.2.14.
Chapter 2 Installation Preparing for Installation Warning The plug-socket combination must be accessible at all times because it serves as the main disconnecting device. Warning To prevent the switch from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 113° F (45° C). To prevent airflow restriction, allow at least 3 inches (7.6 cm) of clearance around the ventilation openings.
Chapter 2 Installation Preparing for Installation Warning Class 1 laser product Warning Avoid exposure to the laser beam. EMC Regulatory Statements This section includes specific regulatory statements about the Catalyst 2950 switches. U.S.A. U.S. regulatory information for this product is in the front matter of this manual. Taiwan This is a Class A Information product. When used in a residential environment, it may cause radio frequency interference.
Chapter 2 Installation Preparing for Installation Japan 46464 This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. Korea Warning This is a Class A Device and is registered for EMC requirements for industrial use.
Chapter 2 Installation Preparing for Installation Hungary This equipment is a Class A product and should be used and installed properly according to the Hungarian EMC Class A requirements (MSZEN55022). Class A equipment is designed for typical commercial establishments for which special conditions of installation and protection distance are used.
Chapter 2 Installation Preparing for Installation • Operating environment is within the ranges listed in Appendix A, “Technical Specifications.” • Clearance to front and rear panels meet these conditions: – Front-panel LEDs can be easily read. – Access to ports is sufficient for unrestricted cabling. – Rear-panel AC power connector is within reach of an AC power outlet. – Rear-panel direct current (DC) power connector is within reach of a circuit breaker.
Chapter 2 Installation Preparing for Installation • Mounting kit containing these items: – Four rubber feet for mounting the switch on a table, shelf, or desk – Two 19-inch or 24-inch rack-mounting brackets – Six number-8 Phillips flat-head screws for attaching the brackets to the switch – Four number-8 Phillips truss-head screws for attaching the brackets to the switch – Four number-12 Phillips machine screws for attaching the brackets to a rack – One cable guide and one black Phillips machine screw
Chapter 2 Installation Installing the Switch in a Rack You can connect a 100BASE-FX or 1000BASE-SX port to an SC or ST port on a target device by using one of the MT-RJ fiber-optic patch cables listed in Table 2-1. Use the Cisco part numbers in Table 2-1 to order the patch cables that you need.
Chapter 2 Installation Installing the Switch in a Rack To install the switch in a 19-, 23-, or 24-inch rack, follow these steps: Note • Attaching the Brackets to the Switch, page 2-10 • Mounting the Switch in a Rack, page 2-19 • Attaching the Optional Cable Guide, page 2-19 Installing the Catalyst 2950G-48-EI switch in a 23-inch or 24-inch rack requires an optional bracket kit not included with the switch.
Chapter 2 Installation Installing the Switch in a Rack Figure 2-1 Attaching Brackets on the Switch in a 19-Inch Rack (Front Panel Forward) SYST RPS STAT 1x 2x 3x UTIL DU PLX SP EED 4x 5x 45580 MODE Number-8 Phillips flat-head screws Figure 2-2 Attaching Brackets on the Switch in a 19-Inch Rack (Rear Panel Forward) CONSOL Number-8 Phillips flat-head screws 52916 E Catalyst 2950 Desktop Switch Hardware Installation Guide 78-11157-03 2-11
Chapter 2 Installation Installing the Switch in a Rack Figure 2-3 Attaching Brackets on the Switch in a 19-Inch Telco Rack CONSOL E Figure 2-4 45582 Number-8 Phillips flat-head screws Attaching Brackets on the Catalyst 2950G-48-EI Switch in a 19-Inch Rack (Front Panel Forward) 1 SYST RPS 1X STAT UTIL DUPLX 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SPEED MODE 15X 2X Number-8 Phillips flat-head screws 65512 16X Catalyst 2950 Desktop Switch Hardware Installation Guide 2-12 78-11
Chapter 2 Installation Installing the Switch in a Rack Figure 2-5 Attaching Brackets on the Catalyst 2950G-48-EI Switch in a 19-Inch Rack (Rear Panel Forward) CONSO LE Attaching Brackets on the Catalyst 2950G-48-EI Switch in a 19-Inch Telco Rack CONSOL E Number-8 Phillips flat-head screws 65514 Figure 2-6 65513 Number-8 Phillips flat-head screws Catalyst 2950 Desktop Switch Hardware Installation Guide 78-11157-03 2-13
Chapter 2 Installation Installing the Switch in a Rack Attaching Brackets on the Catalyst 2950G-24-EI-DC Switch in a 23-Inch Telco Rack (Front Panel Forward) 1 SYST 1X RPS STAT Number-8 Phillips truss-head screws Figure 2-8 3 4 5 6 7 8 9 10 UTIL DU PLX SP EED 11 12 11X MODE 2X 12X Attaching Brackets on the Catalyst 2950G-24-EI-DC Switch in a 23-Inch Telco Rack (Rear Panel Forward) LE Number-8 Phillips truss-head screws 65674 CONSO 2 65673 Figure 2-7 Catalyst 2950 Desktop Switch
Chapter 2 Installation Installing the Switch in a Rack Figure 2-9 Attaching Brackets on the Catalyst 2950G-24-EI-DC Switch in a 23-Inch Telco Rack CONSOL E 65675 Number-8 Phillips truss-head screws Figure 2-10 Attaching Brackets on the Switch in a 24-Inch Rack (Front Panel Forward) 1 SYST 1X RPS Number-8 Phillips truss-head screws 3 4 5 6 7 8 9 10 11 UTIL DU PLX SP EED 12 11X MODE 2X 12X 65666 STAT 2 Catalyst 2950 Desktop Switch Hardware Installation Guide 78-11157-03 2-15
Chapter 2 Installation Installing the Switch in a Rack Figure 2-11 Attaching Brackets on the Switch in a 24-Inch Rack (Rear Panel Forward) LE Number-8 Phillips truss-head screws 65665 CONSO Catalyst 2950 Desktop Switch Hardware Installation Guide 2-16 78-11157-03
Chapter 2 Installation Installing the Switch in a Rack Figure 2-12 Attaching Brackets on the Switch in a 24-Inch Telco Rack CONSOL E 65667 Number-8 Phillips truss-head screws Figure 2-13 Attaching Brackets on the Catalyst 2950G-48-EI Switch in a 24-Inch Rack (Front Panel Forward) 1 SYST RPS 1X STAT UTIL 2 3 4 5 6 7 8 9 10 11 DUPLX SPEED 12 13 14 15 16 15X 2X 16X 74528 Phillips flat-head screws MODE Catalyst 2950 Desktop Switch Hardware Installation Guide 78-11157-03 2-17
Chapter 2 Installation Installing the Switch in a Rack Figure 2-14 Attaching Brackets on the Catalyst 2950G-48-EI Switch in a 24-Inch Rack (Rear Panel Forward) Phillips flat-head screws 74529 CONSO LE Figure 2-15 Attaching Brackets on the Catalyst 2950G-48-EI Switch in a 24-Inch Telco Rack 33 33X 34 35 36 37 38 39 40 41 42 43 44 45 46 47 Catalyst 295 0 SERIES 48 47X 34X 1 48X 2 Phillips flat-head screws 74530 24" Configuration Catalyst 2950 Desktop Switch Hardware Installati
Chapter 2 Installation Installing the Switch in a Rack Mounting the Switch in a Rack After attaching the brackets, use the four Phillips machine screws to securely attach the brackets to the rack, as shown in Figure 2-16. To prevent the cables from obscuring the switch and other devices in the rack, you can also attach the cable guide to the rack. See the“Attaching the Optional Cable Guide” section for instructions.
Chapter 2 Installation Installing the Switch on a Table, Shelf, or Desk Figure 2-17 Attaching the Cable Guide SYST RPS STAT UTIL DUPLX 1x 2x SPEED 3x 4x 5x 6x 7x 8x 9x 10x 11x 10Base-T / 100Base-T X 12x 13x 14x 15x 16x 17x 18x 19x 20x Catalyst 2950 21x 22x 23x SERIES 24x 45573 MODE Cable guide screw Installing the Switch on a Table, Shelf, or Desk Before placing the switch on a table, shelf, or desk, locate the adhesive strip with rubber feet in the mounting-kit envelope, a
Chapter 2 Installation Installing the GBIC Modules Caution To prevent electrostatic-discharge (ESD) damage when installing GBIC modules, follow your normal board and component handling procedures.
Chapter 2 Installation Powering On the Switch Figure 2-20 Installing a GigaStack GBIC Module in a Switch Metal flap door 1 Catalyst 29 50 SERIES GigaStack GBIC module GBIC module slot 74533 2 Powering On the Switch Before connecting the AC power cord, a DC-input power source, or the Redundant Power System (RPS) to the switch, make sure that you have started the terminal-emulation software (such as ProComm, HyperTerminal, tip, or minicom) from your management station.
Chapter 2 Installation Connecting to DC Power Connecting to DC Power To connect the Catalyst 2950G-24-EI-DC switch to a DC-input power source, follow these steps: • Preparing for Installation, page 2-23 • Grounding the Switch, page 2-24 • Wiring the DC-Input Power Source, page 2-26 Warning The Catalyst 2950G-24-EI-DC contains no field-replaceable units (FRUs). Do not open the chassis or attempt to remove or replace any components.
Chapter 2 Installation Connecting to DC Power Grounding the Switch Warning This equipment is intended to be grounded. Ensure that the host is connected to earth ground during normal use. Warning When installing the unit, always make the ground connection first and disconnect it last. Caution To make sure that the equipment is reliably connected to earth ground, follow the grounding procedure instructions, and use a UL-listed lug suitable for number-6 AWG wire and two number-10-32 ground-lug screws.
Chapter 2 Installation Connecting to DC Power Step 4 Using a Panduit crimping tool, crimp the ground lug to the 6-gauge wire. 60529 Figure 2-22 Crimping the Ground Lug Step 5 Use the two number-10-32 screws to attach the ground lug and wire assembly to the switch rear panel. Step 6 Using a ratcheting torque screwdriver, torque each ground-lug screw to 15 lbf-in. (240 ounce-force inches [ozf-in.]).
Chapter 2 Installation Connecting to DC Power Figure 2-23 Torquing Ground-Lug Screws 36 - 72V 1 - 0.5A A B DC INPUT FO POWE R REMOTE SPECIF R SUPPLY IED IN +12V @4MANUAL. .5A 65295 CONSOLE Torque to 15 lbf-in. Wiring the DC-Input Power Source Warning Only trained and qualified personnel should be allowed to install or replace this equipment. Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Chapter 2 Installation Connecting to DC Power Caution You must connect the Catalyst 2950G-24-EI-DC switch only to a DC-input power source that has an input supply voltage from –36 to –72 VDC. If the supply voltage is not in this range, the switch might not operate properly or might be damaged. Caution The switch must be installed with 5A-branch-circuit protection. Note This installation must comply with all applicable codes.
Chapter 2 Installation Connecting to DC Power Step 2 Identify the positive and negative feed positions for the terminal block connection. The wiring sequence is positive to positive and negative to negative for both the A and the B feed wires. The switch rear panel identifies the positive and negative positions for both the A and B feed wires. Figure 2-25 Positive and Negative Positions on the Switch Rear Panel 36 - 72V 1 - 0.
Chapter 2 Installation Connecting to DC Power Warning An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure that no exposed portion of the DC-input power source wire extends from the terminal block plug. Figure 2-27 Inserting Wires in the Terminal Block Plug Feed A Feed B 60532 Return Negative Return Negative Step 5 Caution Use a ratcheting torque screwdriver to torque the terminal block captive screw (above the installed wire lead) to 4.5 lbf-in.
Chapter 2 Installation Connecting to DC Power Figure 2-28 Torquing the Terminal-Block Captive Screws 60533 Torque to 4.5 lbf-in. (72 ozf-in.
Chapter 2 Installation Connecting to DC Power Step 6 Repeat Steps 4 and 5 for the remaining three DC-input power source wires. Figure 2-29 shows the completed wiring of a terminal block plug. Figure 2-29 Completed Wiring of Terminal Block Plug Feed A Feed B 60534 Return Negative Return Negative Step 7 Insert the terminal block plug in the terminal block header on the switch rear panel (see Figure 2-30).
Chapter 2 Installation Running POST Figure 2-30 Inserting the Terminal Block in the Block Header 36 - 72V 1 - 0.5A DC INPUT FO POWE R REMOTE SPECIF R SUPPLY IED IN +12V @4MANUAL. .5A A B 65293 CONSOLE Tie wrap Step 8 Remove the tape from the circuit-breaker switch handle, and move the circuit-breaker handle to the on position. Running POST After the power is connected, the switch automatically begins POST, a series of tests that verifies that the switch functions properly.
Chapter 2 Installation Connecting to 10/100 and 10/100/1000 Ports Connecting to 10/100 and 10/100/1000 Ports The 10/100 ports configure themselves to operate at the speed and duplex settings of attached devices.They operate at 10 or 100 Mbps in half- or full-duplex mode. If the attached devices do not support autonegotiation, you can explicitly set the speed and duplex parameters. The 10/100/1000 ports configure themselves to operate at the speed setting of attached devices.
Chapter 2 Installation Connecting to 10/100 and 10/100/1000 Ports Follow these steps to connect the switch to 10BASE-T, 100BASE-TX, or 1000BASE-T devices: Caution To prevent electrostatic-discharge (ESD) damage, follow your normal board and component handling procedures. Step 1 When connecting to servers, workstations, and routers, insert a twisted-pair straight-through cable in a front-panel RJ-45 connector, as shown in Figure 2-31, Figure 2-32, and Figure 2-33.
Chapter 2 Installation Connecting to 10/100 and 10/100/1000 Ports Figure 2-32 Connecting to a Port on Catalyst 2950G-12-EI, 2950G-24-EI, and 2950G-24-EI-DC Switches 1 1X RPS STAT 2 3 4 5 6 7 8 9 10 11 UTIL D UPLX S PEED MODE 12 11X 2X 12X 65394 SYST Catalyst 2950 Desktop Switch Hardware Installation Guide 78-11157-03 2-35
Chapter 2 Installation Connecting to 10/100 and 10/100/1000 Ports Figure 2-33 Connecting to a Port on Catalyst 2950G-48-EI Switches 1 SYST RPS 2 3 4 1X 5 6 7 STAT UTIL DUPLX 8 9 10 11 12 13 14 15 16 SPEED 15X 2X 16X Step 2 Insert the other cable end in an RJ-45 connector on the target device. Step 3 Observe the port status LED. 65517 MODE The LED turns green when the switch and the target device have an established link.
Chapter 2 Installation Connecting to 100BASE-FX and 1000BASE-SX Ports Connecting to 100BASE-FX and 1000BASE-SX Ports The 100BASE-FX and 1000BASE-SX ports operate only in full-duplex mode. You can connect a 100BASE-FX or 1000BASE-SX port to an SC or ST port on another device by using one of the MT-RJ fiber-optic patch cables listed in Table 2-1. Use the Cisco part numbers in Table 2-1 to order the patch cables that you need.
Chapter 2 Installation Connecting to GBIC Module Ports Step 3 Insert the other cable end in an SC or ST port on the target device. Step 4 Observe the port status LED. The LED turns green when the switch and the target device have an established link. The LED turns amber while STP discovers the network topology and searches for loops. This process takes about 30 seconds, and then the port LED turns green.
Chapter 2 Installation Connecting to GBIC Module Ports When connecting the ports on the Catalyst 2950G-24-EI-DC switches to other devices, follow these guidelines: Caution To comply with the intrabuilding lightning surge requirements, intrabuilding wiring must be shielded, and the shield for the wiring must be grounded at both ends. Caution The Catalyst 2950G-24-EI-DC switch is suitable only for intrabuilding or nonexposed wiring connections.
Chapter 2 Installation Connecting to GBIC Module Ports Figure 2-35 Connecting to a 1000 BASE-X GBIC Port 1 Catalyst 29 50 SERIES 65296 2 Step 3 Insert the other cable end in a fiber-optic receptacle on a target device. Step 4 Observe the port status LED. The LED turns green when the switch and the target device have an established link. The LED turns amber while STP discovers the network topology and searches for loops. This process takes about 30 seconds, and then the port LED turns green.
Chapter 2 Installation Connecting to GBIC Module Ports Connecting to 1000BASE-T GBIC Module Ports After installing the 1000BASE-T GBIC in the GBIC module slot, follow these steps: Caution Step 1 Note To prevent ESD damage, follow your normal board and component handling procedures. When connecting to servers, workstations, and routers, insert a four twisted-pair, straight-through cable in the RJ-45 connector.
Chapter 2 Installation Connecting to GBIC Module Ports Step 3 Observe the port status LED. The LED turns green when the switch and the target device have an established link. The LED turns amber while STP discovers the network topology and searches for loops. This process takes about 30 seconds, and then the LED turns green. If the LED is off, the target device might not be turned on, there might be a cable problem, or there might be a problem with the adapter installed in the target device.
Chapter 2 Installation Connecting a PC or a Terminal to the Console Port Step 3 Observe the port status LED. The LED turns green when the switch and the target device have an established link. The LED turns amber while STP discovers the network topology and searches for loops. This process takes about 30 seconds, and then the port LED turns green.
Chapter 2 Installation Connecting a PC or a Terminal to the Console Port After gaining access to the switch, you can change the port baud rate. Refer to the switch software configuration guide for instructions. Step 3 Insert the adapter cable in the console port, as shown in Figure 2-38, Figure 2-39, and Figure 2-40. (See the “Cable and Adapter Pinouts” section on page B-10 for pinout descriptions.) RATING 100-127V~ @ 1A 200-240V~ @0.
Chapter 2 Installation Where to Go Next Figure 2-40 Connecting to a Console Port Only on Catalyst 2950G-48-EI Switches 200-240V~ @0.5A 50-60Hz DC INPUT FO POWE R REMOTE SPECIF R SUPPLY IED IN +12V @4MANUAL. .5A 74591 RATING 100-127V~ @ 1A CONSOLE RJ-45-to-DB-9 adapter cable Step 4 Attach the appropriate adapter to the terminal, if needed. Step 5 Insert the other adapter cable end in the PC or terminal adapter. Step 6 Start the terminal-emulation software.
Chapter 2 Installation Where to Go Next Catalyst 2950 Desktop Switch Hardware Installation Guide 2-46 78-11157-03
C H A P T E R 3 Troubleshooting The front-panel LEDs provide troubleshooting information about the switch. They show power-on self-test (POST) failures, port-connectivity problems, and overall switch performance. For a full description of the LEDs, see the “LEDs” section on page 1-9.
Chapter 3 Troubleshooting Understanding POST Results Understanding POST Results While the switch powers on, it automatically begins POST, a series of tests that verifies that the switch functions properly. When the switch begins POST, the system LED is off. If POST completes successfully, the LED turns green. If POST fails, the LED turns amber. Note POST failures are usually fatal. Call Cisco Systems if your switch does not pass POST.
Chapter 3 Troubleshooting Diagnosing Problems Table 3-1 Common Problems and Solutions Symptom Possible Cause Resolution Poor performance or excessive errors. Duplex autonegotiation mismatch. Refer to the switch software configuration guide for information about identifying autonegotiation mismatches. Cabling distance exceeded. • Port statistics show excessive frame check sequence (FCS), late-collision, or alignment errors.
Chapter 3 Troubleshooting Diagnosing Problems Table 3-1 Common Problems and Solutions (continued) Symptom Possible Cause No connectivity. Incorrect or bad cable. Resolution No link at both ends. • A crossover cable was used when a straight-through was required, or vice-versa. • For the correct pinouts and the proper application of crossover vs. straight-through cables, see the “Cable and Adapter Specifications” section on page B-7. • The cable is wired incorrectly.
Chapter 3 Troubleshooting Diagnosing Problems Table 3-1 Common Problems and Solutions (continued) Symptom System LED is amber Possible Cause • Internal fan fault detected. Resolution • Check if the fan has failed by using the show env fan privileged EXEC command. If the fan has failed, call Cisco Systems. • Switch placed in error-disabled state after GBIC module is inserted Nonfatal or fatal POST error detected. Bad or non-Cisco-approved GBIC module.
Chapter 3 Troubleshooting Diagnosing Problems Catalyst 2950 Desktop Switch Hardware Installation Guide 3-6 78-11157-03
A P P E N D I X A Technical Specifications Table A-1, Table A-2, Table A-3, and Table A-4 list the technical specifications for the Catalyst 2950 switches. Table A-5 and Table A-6 list the regulatory agency approvals.
Appendix A Table A-1 Technical Specifications Technical Specifications for Catalyst 2950-12, 2950-24, 2950C-24, 2950SX-24, and 2950T-24 Switches (continued) Physical Dimensions Weight 6.5 lb (3 kg) Dimensions (H x W x D) 1.72 x 17.5 x 9.52 in. (4.36 x 44.45 x 24.
Appendix A Technical Specifications Table A-2 Technical Specifications for Catalyst 2950G-12-EI, 2950G-24-EI, and 2950G-48-EI Switches (continued) Catalyst 2950G-12-EI and 2950G-24-EI Switches Catalyst 2950G-48-EI Switch Weight 6.5 lb (3 kg) 10.5 lb (4.8 kg) Dimensions (H x W x D) 1.72 x 17.5 x 9.52 in. (4.36 x 44.45 x 24.18 cm) 1.72 x 17.5 x 13 in. (4.36 x 44.45 x 33.
Appendix A Table A-4 Technical Specifications Fiber-Port Specifications for Catalyst 2950C-24 and Catalyst 2950SX-24 Switches Fiber-Port Power Levels Catalyst 2950C-24 nm1 Optical transmitter wavelength 1300 Optical receiver sensitivity –34.5 to 31.8 dBm2 Catalyst 2950SX-24 850 nm –13.5 dBm Optical transmitter power –23.5 to –14 dBm for 50/125-micron cabling –9.5 to –4 dBm Optical transmitter power –20 to –14 dBm for 62.5/125-micron cabling –9.5 to –4 dBm 1. nm = nanometers 2.
Appendix A Technical Specifications Table A-6 Catalyst 2950G-24-EI-DC Switch Agency Approvals NEBS Bellcore GR-1089-CORE Bellcore GR-63-CORE Bellcore SR-3580 Level 3 Catalyst 2950 Desktop Switch Hardware Installation Guide 78-11157-03 A-5
Appendix A Technical Specifications Catalyst 2950 Desktop Switch Hardware Installation Guide A-6 78-11157-03
A P P E N D I X B Connectors and Cables This appendix describes the connectors, cables, and adapters that you use to connect the switch to other devices.
Appendix B Connectors and Cables Connector Specifications When connecting 10/100 ports to other devices, such as servers, workstations, and routers, you can use a two or four twisted-pair, straight-through cable wired for 10BASE-T and 100BASE-TX. Figure B-6 shows the two twisted-pair, straight-through cable schematics. Figure B-8 shows the four twisted-pair, straight-through cable schematics.
Appendix B Connectors and Cables Connector Specifications 10/100/1000 Ports The 10/100/1000 Ethernet ports on Catalyst 2950T-24 switches use standard RJ-45 connectors. Figure B-2 shows the pinout. Connecting to 10BASE-T and 100BASE-TX Devices When connecting the ports to 10BASE-T and 100BASE-TX devices, such as servers, workstations, and routers, you can use a two or four twisted-pair, straight-through cable wired for 10BASE-T and100BASE-TX.
Appendix B Connectors and Cables Connector Specifications RJ-45 Pinouts for 10/100/1000 and 1000BASE-T GBIC Module Ports Pin Label 1 TP0+ 2 TP0- 3 TP1+ 4 TP2+ 5 TP2- 6 TP1- 7 TP3+ 8 TP3- 1234567 8 34751 Figure B-2 100BASE-FX and 1000BASE-SX Ports The 100BASE-FX and 1000BASE-SX ports use MT-RJ connectors, shown in Figure B-3. These ports use 50/125- or 62.5/125-micron multimode fiber-optic cabling.
Appendix B Connectors and Cables Connector Specifications Table B-1 MT-RJ Patch Cables for 100BASE-FX and 1000BASE-SX Connections Type Cisco Part Number 1-meter, MT-RJ-to-SC multimode cable CAB-MTRJ-SC-MM-1M 3-meter, MT-RJ-to-SC multimode cable CAB-MTRJ-SC-MM-3M 5-meter, MT-RJ-to-SC multimode cable CAB-MTRJ-SC-MM-5M 1-meter, MT-RJ-to-ST multimode cable CAB-MTRJ-ST-MM-1M 3-meter, MT-RJ-to-ST multimode cable CAB-MTRJ-ST-MM-3M 5-meter, MT-RJ-to-ST multimode cable CAB-MTRJ-ST-MM-5M 1000BASE-X
Appendix B Connectors and Cables Connector Specifications GigaStack GBIC Module Ports The GigaStack GBIC module ports use proprietary connectors, as shown in Figure B-5. The GigaStack GBIC cables are proprietary, high-data-rate cables with enhanced signal integrity and EMI protection. Caution Do not use standard IEEE 1394 cables with the GigaStack GBIC. GigaStack Connector 60536 Figure B-5 Console Port The console port uses an 8-pin RJ-45 connector.
Appendix B Connectors and Cables Cable and Adapter Specifications Cable and Adapter Specifications These sections describe the cables and adapters used with Catalyst 2950 switches. • Two Twisted-Pair Cable Pinouts, page B-7 • Four Twisted-Pair Cable Pinouts for 10/100 Ports, page B-8 • Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports, page B-9 Two Twisted-Pair Cable Pinouts Figure B-6 and Figure B-7 show the schematics of two twisted-pair cables for 10/100 ports.
Appendix B Connectors and Cables Cable and Adapter Specifications Four Twisted-Pair Cable Pinouts for 10/100 Ports Figure B-8 and Figure B-9 show the schematics of four twisted-pair cables for 10/100 ports.
Appendix B Connectors and Cables Cable and Adapter Specifications Four Twisted-Pair Cable Pinouts for 1000BASE-T Ports Figure B-10 and Figure B-11 show the schematics of four twisted-pair cables for 10/100/1000 ports on Catalyst 2950T-24 switches and 1000BASE-T GBIC module ports.
Appendix B Connectors and Cables Cable and Adapter Specifications Cable and Adapter Pinouts This section describes the cable and adapter pinouts and also describes how to identify a rollover cable. Connecting to a PC Use the supplied RJ-45-to-DB-9 adapter cable to connect the console port to a PC running terminal-emulation software. Figure B-12 shows how to connect the console port to a PC. Table B-2 lists the pinouts for the console port and the RJ-45-to-DB-9 adapter cable.
Appendix B Connectors and Cables Cable and Adapter Specifications Connecting to a Terminal Use the supplied RJ-45-to-DB-9 adapter cable and an RJ-45-to-DB-25 female DTE adapter to connect the console port to a terminal. Figure B-13 shows how to connect the console port to a terminal. Table B-3 lists the pinouts for the console port, the adapter cable, and the RJ-45-to-DB-25 adapter. Note The RJ-45-to-DB-25 female DTE adapter is not supplied with the switch.
Appendix B Connectors and Cables Cable and Adapter Specifications Identifying a Rollover Cable You can identify a rollover cable by comparing the two modular cable ends. Hold the cable ends side-by-side, with the tab at the back. The wire connected to the pin on the outside of the left plug should be the same color as the wire connected to the pin on the outside of the right plug. (See Figure B-14.
A P P E N D I X C Translated Safety Warnings This appendix repeats in multiple languages the warnings in this guide. These translated warnings can be used with other documents related to this guide.
Appendix C Translated Safety Warnings Attaching the Cisco RPS (model PWR300-AC-RPS-N1) Attaching the Cisco RPS (model PWR300-AC-RPS-N1) Warning Waarschuwing: Varoitus Avertissement : Warnung: Avvertenza. Advarsel! Attach only the Cisco RPS (model PWR300-AC-RPS-N1) to the RPS receptacle. Slechts de Cisco RPS (model PWR300-AC-RPS-N1) aan de RPS contactdoos verbinden. Kiinnitä RPS-vastakappaleeseen vain Cisco RPS (malli PWR300-AC-RPS-N1).
Appendix C Translated Safety Warnings Lightning Activity Warning Lightning Activity Warning Warning Waarschuwing Varoitus Do not work on the system or connect or disconnect cables during periods of lightning activity. Tijdens onweer dat gepaard gaat met bliksem, dient u niet aan het systeem te werken of kabels aan te sluiten of te ontkoppelen. Älä työskentele järjestelmän parissa äläkä yhdistä tai irrota kaapeleita ukkosilmalla.
Appendix C Translated Safety Warnings Installation Warning Installation Warning Warning Waarschuwing Varoitus Read the installation instructions before you connect the system to its power source. Raadpleeg de installatie-aanwijzingen voordat u het systeem met de voeding verbindt. Lue asennusohjeet ennen järjestelmän yhdistämistä virtalähteeseen. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation.
Appendix C Translated Safety Warnings Main Disconnecting Device Main Disconnecting Device Warning Waarschuwing Varoitus The plug-socket combination must be accessible at all times because it serves as the main disconnecting device. De combinatie van de stekker en het elektrisch contactpunt moet te allen tijde toegankelijk zijn omdat deze het hoofdmechanisme vormt voor verbreking van de aansluiting. Pistoke/liitinkohta toimii pääkatkaisumekanismina. Pääsy siihen on pidettävä aina esteettömänä.
Appendix C Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing Chassis Warning—Rack-Mounting and Servicing Warning Waarschuwing To prevent bodily injury when mounting or servicing this unit in a rack, you must take special precautions to ensure that the system remains stable. The following guidelines are provided to ensure your safety: • This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
Appendix C Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing Varoitus Attention Kun laite asetetaan telineeseen tai huolletaan sen ollessa telineessä, on noudatettava erityisiä varotoimia järjestelmän vakavuuden säilyttämiseksi, jotta vältytään loukkaantumiselta. Noudata seuraavia turvallisuusohjeita: • Jos telineessä ei ole muita laitteita, aseta laite telineen alaosaan.
Appendix C Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing Warnung Avvertenza Zur Vermeidung von Körperverletzung beim Anbringen oder Warten dieser Einheit in einem Gestell müssen Sie besondere Vorkehrungen treffen, um sicherzustellen, daß das System stabil bleibt. Die folgenden Richtlinien sollen zur Gewährleistung Ihrer Sicherheit dienen: • Wenn diese Einheit die einzige im Gestell ist, sollte sie unten im Gestell angebracht werden.
Appendix C Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing Advarsel Aviso Unngå fysiske skader under montering eller reparasjonsarbeid på denne enheten når den befinner seg i et kabinett. Vær nøye med at systemet er stabilt. Følgende retningslinjer er gitt for å verne om sikkerheten: • Denne enheten bør monteres nederst i kabinettet hvis dette er den eneste enheten i kabinettet.
Appendix C Translated Safety Warnings Chassis Warning—Rack-Mounting and Servicing ¡Advertencia! Varning! Para evitar lesiones durante el montaje de este equipo sobre un bastidor, o posteriormente durante su mantenimiento, se debe poner mucho cuidado en que el sistema quede bien estable. Para garantizar su seguridad, proceda según las siguientes instrucciones: • Colocar el equipo en la parte inferior del bastidor, cuando sea la única unidad en el mismo.
Appendix C Translated Safety Warnings Overtemperature Warning Overtemperature Warning Warning To prevent the switch from overheating, do not operate it in an area that exceeds the maximum recommended ambient temperature of 104°F (40°C). To prevent airflow restriction, allow at least 3 inches (7.6 cm) of clearance around the ventilation openings.
Appendix C Translated Safety Warnings No On/Off Switch Warning Advarsel For å unngå at bryteren overopphetes skal utstyret ikke brukes på steder hvor anbefalt maks omgivelsestemperatur overstiger 104 grader Farenheit (40°C). La det være minst 3 tommer (7,6 cm) klaring rundt ventilasjonsåpningene for at luftsirkulasjonen skal være uhindret. Aviso Para evitar sobreaquecimento do interruptor, não utilize o equipamento numa àrea que exceda uma temperatura máxima de 40°C.
Appendix C Translated Safety Warnings Grounded Equipment Warning Attention Avant de travailler sur un système non équipé d'un commutateur marche-arrêt, débrancher le cordon d'alimentation. Warnung Bevor Sie an einem System ohne Ein/Aus-Schalter arbeiten, ziehen Sie das Netzkabel heraus. Avvertenza Advarsel Aviso ¡Advertencia! Varning! Prima di lavorare su un sistema che non è dotato di un interruttore on/off, scollegare il cavo di alimentazione.
Appendix C Translated Safety Warnings Product Disposal Warning Attention Cet équipement doit être relié à la terre. S’assurer que l’appareil hôte est relié à la terre lors de l’utilisation normale. Warnung Dieses Gerät muß geerdet werden. Stellen Sie sicher, daß das Host-Gerät während des normalen Betriebs an Erde gelegt ist. Avvertenza Questa apparecchiatura deve essere collegata a massa. Accertarsi che il dispositivo host sia collegato alla massa di terra durante il normale utilizzo.
Appendix C Translated Safety Warnings Ground Connection Warning Attention La mise au rebut définitive de ce produit doit être effectuée conformément à toutes les lois et réglementations en vigueur. Warnung Dieses Produkt muß den geltenden Gesetzen und Vorschriften entsprechend entsorgt werden. Avvertenza L'eliminazione finale di questo prodotto deve essere eseguita osservando le normative italiane vigenti in materia.
Appendix C Translated Safety Warnings Ground Connection Warning Attention Lors de l’installation de l’appareil, la mise à la terre doit toujours être connectée en premier et déconnectée en dernier. Warnung Der Erdanschluß muß bei der Installation der Einheit immer zuerst hergestellt und zuletzt abgetrennt werden. Avvertenza In fase di installazione dell'unità, eseguire sempre per primo il collegamento a massa e disconnetterlo per ultimo.
Appendix C Translated Safety Warnings Jewelry Removal Warning Jewelry Removal Warning Warning Before working on equipment that is connected to power lines, remove jewelry (including rings, necklaces, and watches). Metal objects will heat up when connected to power and ground and can cause serious burns or weld the metal object to the terminals. Waarschuwing Alvorens aan apparatuur te werken die met elektrische leidingen is verbonden, sieraden (inclusief ringen, kettingen en horloges) verwijderen.
Appendix C Translated Safety Warnings Jewelry Removal Warning Avvertenza Prima di intervenire su apparecchiature collegate alle linee di alimentazione, togliersi qualsiasi monile (inclusi anelli, collane, braccialetti ed orologi). Gli oggetti metallici si riscaldano quando sono collegati tra punti di alimentazione e massa: possono causare ustioni gravi oppure il metallo può saldarsi ai terminali.
Appendix C Translated Safety Warnings Stacking the Chassis Warning Stacking the Chassis Warning Warning Waarschuwing Varoitus Do not stack the chassis on any other equipment. If the chassis falls, it can cause severe bodily injury and equipment damage. Het chassis mag niet op andere apparatuur gestapeld te worden. Als het chassis mocht vallen, kan dit ernstig lichamelijk letsel en beschadiging van de apparatuur veroorzaken. Älä aseta asennuspohjaa minkään muun laitteen päälle.
Appendix C Translated Safety Warnings Qualified Personnel Warning ¡Atención! Varning No apilar los chasis sobre ningún otro equipo. Si el chasis se cae al suelo puede causar graves lesiones físicas y daños al equipo. Placera inte chassit ovanpå annan utrustning. Om chassit faller kan allvarlig kroppsskada såväl som skada på utrustningen uppstå.
Appendix C Translated Safety Warnings Class 1 Laser Product Warning ¡Atención! Varning Estos equipos deben ser instalados y reemplazados exclusivamente por personal técnico adecuadamente preparado y capacitado. Denna utrustning ska endast installeras och bytas ut av utbildad och kvalificerad personal. Class 1 Laser Product Warning Warning Waarschuwing: Varoitus: Avertissement : Warnung: Avvertenza.
Appendix C Translated Safety Warnings Laser Beam Exposure Warning Laser Beam Exposure Warning Warning Waarschuwing Varoitus Avoid exposure to the laser beam. Vermijd blootstelling aan de straal. Vältä säteelle altistumista. Attention Eviter toute exposition au faisceau. Warnung Schützen Sie sich vor Strahlung. Avvertenza Advarsel Aviso ¡Advertencia! Varning! Evitare l’esposizione al raggio. Unngå å bli utsatt for strålen. Evite exposição ao raio. Evitar la exposición al haz.
Appendix C Translated Safety Warnings Catalyst 2950G-24-EI-DC Service Requirement Catalyst 2950G-24-EI-DC Service Requirement Warning The Catalyst 2950G-24-EI-DC contains no field-replaceable units (FRUs). Do not open the chassis or attempt to remove or replace any components. For information about obtaining service for this unit, contact your reseller or Cisco sales representative. Waarschuwing De Catalyst 2950G-24-EI-DC bevat geen FRU's (field-replaceable units ofwel veldvervangbare eenheden).
Appendix C Translated Safety Warnings Restricted Area Equipment Installation Advarsel Catalyst 2950G-24-EI-DC inneholder ingen kunde-utskiftbare deler (FRU-deler). Gjør ikke forsøk på å åpne kabinettet eller fjerne eller skifte ut noen av komponentene. Ta kontakt med forhandleren eller en Cisco-salgsrepresentant for informasjon om hvor det kan utføres service på enheten. Aviso O interruptor Catalisador 2950G-24-EI-DC não contém nenhuma unidade substituível em campo.
Appendix C Translated Safety Warnings Ethernet Cable Shielding in Offices Attention Cet équipement doit être installé uniquement dans une zone à accès limité. Warnung Die Ausrüstung muß in einem Bereich installiert werden, der gegen unbefugtes Betreten geschützt ist. Avvertenza Installate questo apparato unicamente in zone di accesso regolamentate. Advarsel Utstyret skal installeres på et sted med begrenset adgang.
Appendix C Translated Safety Warnings DC Power Disconnection Warning Warnung Avvertenza Advarsel Aviso ¡Advertencia! Varning! Ethernet-Kabel müssen abgeschirmt werden, wenn sie in einer Zentrale eingesetzt werden. I cavi Ethernet devono essere schermati se utilizzati in un ambiente di ufficio centrale. Ethernet-kabler skal være skjermet når de brukes i et sentralt kontormiljø. Os cabos “Ethernet” deverão estar armados quando usados em ambiente de escritório central.
Appendix C Translated Safety Warnings DC Power Disconnection Warning Varoitus Varmista, että tasavirtapiirissä ei ole virtaa ennen seuraavien toimenpiteiden suorittamista. Varmistaaksesi, että virta on KATKAISTU täysin, paikanna tasavirrasta huolehtivassa kojetaulussa sijaitseva suojakytkin, käännä suojakytkin KATKAISTU-asentoon ja teippaa suojakytkimen varsi niin, että se pysyy KATKAISTU-asennossa.
Appendix C Translated Safety Warnings DC Power Disconnection Warning Aviso Antes de executar um dos seguintes procedimentos, certifique-se que desligou a fonte de alimentação de energia do circuito de corrente contínua. Para se assegurar que toda a corrente foi DESLIGADA, localize o disjuntor no painel que serve o circuito de corrente contínua e coloque-o na posição OFF (Desligado), segurando nessa posição a manivela do interruptor do disjuntor com fita isoladora.
Appendix C Translated Safety Warnings Exposed DC Power Wire Warning Exposed DC Power Wire Warning Warning Waarschuwing An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure that no exposed portion of the DC-input power source wire extends from the terminal block plug. Een blootgestelde verbindingsdraad van een ingangsgelijkstroombron kan gevaarlijke elektriciteitsniveaus geleiden.
Appendix C Translated Safety Warnings Service Personnel Warning Aviso Um fio condutor exposto de uma unidade de entrada de DC (corrente contínua) pode transportar níveis perigosos de electricidade. Certifique-se de que nenhuma secção exposta de um fio condutor da fonte de energia de entrada de DC se extende a partir da ficha da placa de terminais. ¡Advertencia! Un cable desnudo de una fuente de entrada de alimentación de corriente directa (DC) puede conducir niveles de electricidad peligrosos.
Appendix C Translated Safety Warnings Service Personnel Warning Warnung Avvertenza Dieses Gerät darf nur von Wartungspersonal gemäß AS/NZS-Definition 3260, Paragraph 1.2.14.3, "Service Personnel", installiert und gewartet werden. Questo apparecchio deve essere installato e mantenuto in efficienza esclusivamente da personale tecnico che soddisfi i requisiti specificati nella sezione 1.2.14.3 sul ‘Service Personnel’ contenuta nelle norme AS/NZS 3260.
Appendix C Translated Safety Warnings Service Personnel Warning Catalyst 2950 Desktop Switch Hardware Installation Guide C-32 78-11157-03
I N D EX Numerics 1000BASE-T GBIC modules (continued) described 1-9 10/100/1000 ports cable lengths 2-6 connecting to 2-33 to 2-36 illustrated 2-21 installing 2-20 1000BASE-X GBIC modules connectors and cables B-3 cable lengths 2-6 described 1-7 connecting to 2-39 to 2-40 illustrated 1-6 connectors B-5 10/100 ports described 1-8 cable lengths 2-6 illustrated 2-21 connecting to 2-33 to 2-36 installing 2-20 connectors and cables B-1 to B-2 100BASE-FX ports described 1-6 to 1-7 cable length
Index adapter pinouts, terminal RJ-45-to-DB-25 B-11 cables (continued) GBIC RJ-45-to-DB-9 B-10 1000BASE-T module 2-41 addresses, assigning IP 2-45 1000BASE-X module 2-39 agency approvals A-4, A-5 CWDM module 2-38 altitude A-1 to A-3 GigaStack module 2-42 autonegotiation MT-RJ 1-8 10/100/1000 ports 1-7 problems, solving 3-3 to 3-4 10/100 ports 1-7 rollover B-12 straight-through connecting to B-2, B-3 B four twisted-pair pinout, 10/100 ports B-8 four twisted-pair pinout, 1000BASE-T ports B-9
Index CiscoView 1-24 connecting (continued) Class 1 laser product warning 2-4, C-21 to 100BASE-FX ports 2-37 to 2-38 clearance 2-7 to AC power 2-22 CLI 1-24 to console port 2-43 to 2-45 Cluster Builder application 1-23 to CWDM GBIC module ports 2-38 Cluster Management Suite to DC power 2-23 to 2-32 See CMS to GBIC module ports 2-38 to 2-43 Cluster Manager application 1-23 to GigaStack GBIC module ports 2-42 Cluster View application 1-23 to PC 2-43 to 2-45 CMS to RPS 2-22 Cluster Builder
Index console port D adapter pinouts RJ-45-to-DB-25 terminal B-11 DC power connecting to 2-23 to 2-32 cable, rollover B-12 connector 1-22 console port (continued) connecting to 2-43 to 2-45, B-10 to B-11 specifications A-3 default characteristics 2-43 warnings 2-23, 2-24, 2-26 illustrated 1-21 to 1-22 DC power disconnection warning 2-26, C-26 RJ-45-to-DB-9 adapter cable pinouts B-10 default characteristics of the console port 2-43 conventions, document xvi to xix desk-mounting 2-20 crossove
Index EMC regulatory statements 2-4 to 2-6 G environmental ranges A-1 to A-3 Ethernet cable warning 2-23, C-25 to C-26 GBIC modules examples, network configuration 1-1 cable lengths 2-6 exposed DC power wire warning 2-29, cables C-29 to C-30 1000BASE-T B-3 1000BASE-X 2-39 CWDM 2-38 F GigaStack B-6 fan problems, solving 3-5 connecting to 2-38 to 2-43 features 1-1 to 1-3 connectors feedback to Cisco Systems, web xxi 1000BASE-T B-4 fiber-port specifications A-4 1000BASE-X B-5 front panel C
Index GigaStack GBIC modules installation (continued) cable lengths 2-6 rack-mount 2-9 to 2-20 connecting to 2-42 shelf-mount 2-20 connectors and cables B-6 table-mount 2-20 described 1-9 warning 2-2, C-4 illustrated 2-22 installing GBIC modules 2-20 to 2-22 installing 2-20 IOS command-line interface See CLI ground connection warning 2-3, 2-24, C-15 to C-16 grounded equipment warning 2-3, 2-24, IP address procedures 2-45 C-13 to C-14 J H jewelry removal warning 2-3, C-17 to C-18 half-duple
Index LEDs (continued) port status 1-13 no on/off switch warning 2-2, C-12 to C-13 notes, defined xvi RPS 1-13 speed (SPEED) 1-14, 1-18 status (STAT) 1-14, 1-17 O system 1-12 obtaining documentation xx to xxii utilization (UTIL) 1-14, 1-17 overtemperature warning 2-3, C-11 to C-12 lightning activity warning 2-3, C-3 P M package contents 2-7 to 2-9 main disconnecting device warning 2-3, C-5 patch cables, MT-RJ 1-8 management options 1-23 to 1-24 PC, connecting to switch 2-43 to 2-45, B-10 Mode
Index pinouts (continued) power (continued) RJ-45-to-DB-25 terminal adapter B-11 supply RJ-45-to-DB-9 adapter cable B-10 AC connector 1-22 RJ-45-to-DB-9 PC adapter cable B-10 DC connector 1-22 straight-through cables RPS connector 1-23 four twisted-pair, 10/100 ports B-8 power connectors 1-22 to 1-23 four twisted-pair, 1000BASE-T ports B-9 power on 2-22 two twisted-pair B-7 procedures port connecting to DC power 2-23 to 2-32 LEDs 1-9 to 1-12, 1-13 connection 2-33 to 2-45 mode installat
Index rear panel (continued) status LED 1-14, 1-17 straight-through cable described 1-20 connecting to illustrated 1-21 to 1-22 10/100/1000 ports 2-34 power connectors 1-22 to 1-23 Redundant Power System 10/100 ports 2-34 1000BASE-T GBIC module ports 2-41 See RPS regulatory statements, EMC 2-4 to 2-6 connectivity problems 3-4 related publications xix to xx pinout restricted access area warning 2-23, C-24 to C-25 four twisted-pair, 10/100 ports B-8 rollover cable B-12 four twisted-pair, 1000B
Index troubleshooting 3-1 diagnosing problems 3-2 to 3-5 understanding POST results 3-2 U URLs, Cisco xx utilization bandwidth 1-17 to 1-20 LED 1-14, 1-17 V verifying package contents 2-7 to 2-9 W warnings DC power 2-23, 2-24, 2-26 defined xvii to xix installation 2-2 to 2-4 translated C-1 to C-31 Catalyst 2950 Desktop Switch Hardware Installation Guide IN-10 78-11157-03