Specifications

Installing the Router 3-11
Connecting the DC Power Supply
Warning When stranded wiring is required, use approved wiring terminations, such as
closed-loop or spade-type with upturned lugs. These terminations should be the appropriate
size for the wires and should clamp both the insulation and conductor. (To see translated
versions of this warning, refer to the Regulatory Compliance and Safety Information
document that accompanied the router.)
Caution Do not overtorque the terminal block captive thumbscrew or terminal block
contact screws. The recommended torque is 8.2 ± 0.4 inch-lb.
Warning After wiring the DC power supply, remove the tape from the circuit breaker
switch handle and reinstate power by moving the handle of the circuit breaker to the on
position. (To see translated versions of this warning, refer to the Regulatory Compliance
and Safety Information document that accompanied the router.)