Specifications
Installation and Startup 2-7
Installing the Switch on a Table or Shelf
• Fatal failure(s) detected—POST completes all tests, even after detecting a fatal failure.
If the SYSTEM LED is amber and one or more of the port LEDs are amber, POST
detected one or more fatal failures. The switch is not operational, the management
console is not available, and the amber port LED(s) indicate which test(s) failed.
The “Understanding POST Failures” section on page 5-7 provides additional information,
including the possible causes of nonfatal and fatal failures. For information about how to
display POST results, see the “Starting Up the Switch and Displaying the POST Results”
section on page 5-12.
Note Inform your system administrator about any POST failures. Contact your Cisco
representative or reseller for support if any POST failures are detected.
Installing the Switch on a Table or Shelf
Caution Before you perform the following steps, be sure the switch is powered off and is
not connected to a power source.
To install the switch on a table or shelf, follow these steps:
Step 1 Locate the adhesive strip with the rubber feet that shipped with the switch.
Step 2 Attach the rubber feet to the round recesses on the bottom corners of the switch.
Step 3 Place the switch on a table or shelf close to an AC power receptacle.
Continue to the procedures in the “Connecting to the Console Port” section on page 2-16.