Specifications

Preparing for Installation
Catalyst 1900 Series Installation and Configuration Guide
2-4
Site Preparation
When determining where to place the switch, ensure the following conditions are met:
Operating environment is within the temperature, humidity, and altitude ranges listed in
Appendix A, “Technical Specifications.
If the switch is installed in a closed or multirack assembly, the temperature might be
greater than normal room temperature.
Airflow around the switch and through the vents is unrestricted.
Cables (such as Category 3, 4, or 5 straight-through or crossover cables and fiber-optic
cables) are at hand to connect the switch to the other devices in your network.
Cable distances from the switch to network equipment and workstations are within the
limits described in Appendix B, “Connectors and Cables.
Clearance to front and rear panels is such that:
Front-panel indicators can be easily read.
Access to the front- and rear-panel ports and connectors is sufficient for connecting
cables.
Rear-panel power connectors are within reach of power sources.
Cabling is away from sources of electrical noise, such as radios, power lines, and
fluorescent lighting fixtures.