Specifications
8-13
Cisco 1700 Series Router Software Configuration Guide
78-5407-03
Chapter 8 Configuring Asynchronous Connections
Asynchronous Dial-In Pool
This configuration example includes multiple interfaces of the same type being
configured with the same commands. When you enter commands for one of the
multiple interfaces, you must enter interface configuration mode for the correct
interface. Table 8-1 shows how the interfaces are numbered in this configuration
example.
Configuring Global Parameters
Follow these steps to configure global parameters.
Table 8-1 Serial Interface Numbering
Line
Interface Name and
Number
1 Serial0
2 Serial1
3 Serial2
4 Serial3
5 (AUX port) Async5
Command Task
Step1
configure terminal Enter configuration mode.
Step2
service timestamps debug datetime msec Configure the router to show the date and
time of all debug messages.
This command is optional, but it is
recommended if you use debug commands to
troubleshoot your configuration.
Step3
service timestamps log datetime msec Configure the router to show the date and
time of all log messages.
This command is optional, but it is
recommended if you use the verification
steps described in this guide. This feature is
enabled for all the command output
examples shown in this guide.