Specifications

Chapter 8 Configuring Asynchronous Connections
Asynchronous Dial-Up Connection
8-10
Cisco 1700 Series Router Software Configuration Guide
78-5407-03
Confirming the Asynchronous Line Configuration
Follow these steps to confirm the configuration of the asynchronous line:
Step 1 From the privileged EXEC mode, enter the show line command. You should see
command output similar to the following:
Router# show line 1
Tty Typ Tx/Rx A Modem Roty AccO AccI Uses Noise
Overruns
A 1 TTY 19200/19200 - - - - - 2 4
0/0
Line 1, Location: "", Type: ""
Length: 24 lines, Width: 80 columns
Baud rate (TX/RX) is 19200/19200, no parity, 1 stopbits, 8 databits
Status: Ready, Active, Async Interface Active, HW PPP Support Active
Capabilities: Line is permanent async interface
Modem state: Ready
Line is running PPP for address 192.168.39.40
0 output packets queued, 0 input packets.
Async Escape map is 00000000000000000101000000000000
Modem hardware state: CTS DSR DTR RTS
Special Chars: Escape Hold Stop Start Disconnect Activation
^^x none - - none
Step 2 Confirm that the Line 1 message appears in the command output.
The asynchronous line settings should be the same as those that you configured in
the Configuring the Asynchronous Interface section on page 8-5.
The IP address in the Line is running message should be the IP address of the
WAN interface of the central-site router.
Configuring When the Router Dials
Follow these steps to configure how and when the router dials the central-site
router.