Chapter 8 Configuring Asynchronous Connections
Asynchronous Dial-Up Connection
8-10
Cisco 1700 Series Router Software Configuration Guide
78-5407-03
Confirming the Asynchronous Line Configuration
Follow these steps to confirm the configuration of the asynchronous line:
Step 1 From the privileged EXEC mode, enter the show line command. You should see
command output similar to the following:
Router# show line 1
Tty Typ Tx/Rx A Modem Roty AccO AccI Uses Noise
Overruns
A 1 TTY 19200/19200 - - - - - 2 4
0/0
Line 1, Location: "", Type: ""
Length: 24 lines, Width: 80 columns
Baud rate (TX/RX) is 19200/19200, no parity, 1 stopbits, 8 databits
Status: Ready, Active, Async Interface Active, HW PPP Support Active
Capabilities: Line is permanent async interface
Modem state: Ready
Line is running PPP for address 192.168.39.40
0 output packets queued, 0 input packets.
Async Escape map is 00000000000000000101000000000000
Modem hardware state: CTS DSR DTR RTS
Special Chars: Escape Hold Stop Start Disconnect Activation
^^x none - - none
Step 2 Confirm that the “Line 1” message appears in the command output.
The asynchronous line settings should be the same as those that you configured in
the “Configuring the Asynchronous Interface” section on page 8-5.
The IP address in the “Line is running” message should be the IP address of the
WAN interface of the central-site router.
Configuring When the Router Dials
Follow these steps to configure how and when the router dials the central-site
router.