Installation guide
1-36
Cisco ONS 15530 Hardware Installation Guide
OL-7706-01
Chapter 1 Cisco ONS 15530 Overview
Cisco ONS 15530 Components
The following warning applies to the copper SFPs listed in Table 1-19.
Warning
For connections outside the building where the equipment is installed, the following ports must be
connected through an approved network termination unit with integral circuit protection.
15500-XVRA-08D1, 15500-XVRA-09D1, 15500-XVRA-10E1 and 15500-XVRA-11D1.
Statement 1044
Note The SFPs must be purchased separately.
2.5-Gbps ITU Trunk Cards
The 2.5-Gbps ITU trunk card sends and receives the ITU grid wavelength signal to and from an OADM
module. This card accepts a 2.5-Gbps (3.125-Gbps line rate) electrical signal from either a 10-port
ESCON aggregation card or an 8-port FC/GE aggregation card, which is converted to the ITU grid
wavelength, or channel. The 2.5-Gbps ITU trunk card has redundant interfaces to the backplane,
connecting to the switch fabrics on the active and standby CPU switch modules. The ITU laser is tunable
to one of two channel frequencies. There are 16 different 2.5-Gbps ITU trunk cards (for channels 1–2,
3–4,..., 31–32) to support the 32 channels.
The 2.5-Gbps ITU trunk card has two versions: nonsplitter (shown in Figure 1-26) and splitter (shown
in Figure 1-27). The nonsplitter version has only one pair of optical connectors on the front panel, which
connects to either the east or the west OADM module, and can be used for unprotected, line card
protected, or switch fabric protected applications. The card supports 32 channels as shown in Table A-2
on page A-3.
15500-XVRA-10E1
2
SDI and DVB-ASI
3
Video Copper Digital
Video
– Mini SMB
Coax
15500-XVRA-11D1
4
GE 1.25 Gbps, FE 1.25
Mbps
Copper GE/FE – RJ-45
1. DSX-1 interface
2. In a normal operating environment, the maximum digital video application connection length using a Belden 1694A cable
is 200 m (218 yd). If the chassis ambient operating temperature is above 45°C (113° F) and ports 0 and 1 are used for video
applications with this SFP, the maximum cable connection length supported may be less than the specified 200 m (218 yd),
depending on the operating environment.
3. Data Video Broadcast Asynchronous Serial Interface
4. To ensure proper operation of the 15500-XVRA-11D1 SFP, the ambient operating temperature should not exceed 45°C
(113°F).
Table 1-19 8-Port Multi-Service Muxponder SFP Characteristics (continued)
Part Number
Protocols or Clock Rate
Range Supported Fiber Type Wavelength
Connector
Type