8-Port FC/GE Aggregation Card
Table A-14 and Table A-15 show the latency value for the various configurations on the transmitting
node.
FC and FICON traffic on interfaces with buffer credits enabled with the flow control command are not
affected by latency.
8-Port FC/GE Aggregation Card
The optical power characteristics of the SFP (small form-factor pluggable) optics for the 8-port Fibre
Channel/Gigabit Ethernet aggregation cards are shown in Table A-16. The optical power characteristics
of the supported SFP optics are listed in the SFP Specifications section. Only use Cisco-certified SFP
optics for the 8-port FC/GE aggregation cards. If the specifications of the client equipment interfaces do
not fall within these ranges, attenuators or amplifiers might be required.
Table A-14 1-Gbps FC and FICON Latency Values for 4-Port 1-Gbps/2-Gbps Aggregation Cards
Traffic Mix on Transmitting Node
Maximum Added End-to-End Latency
No GE
1518-Byte
GE Packets
4470-Byte
GE Packets
10,232-Byte
GE Packets
FC/FICON only on the 2.5-Gbps aggregated signal carried over
a 2.5-Gbps ITU trunk card (single port in the portgroup)
12.2 micro
seconds
FC/FICON only on the 2.5-Gbps aggregated signal carried over
a 2.5-Gbps ITU trunk card (two ports in the portgroup)
12.7 micro
seconds
FC/FICON only on a 2.5-Gbps aggregated signal carried over a
10-Gbps ITU trunk card (single port in the portgroup)
11.6 micro
seconds
FC/FICON only on a 2.5-Gbps aggregated signal carried over a
10-Gbps ITU trunk card (two ports in the portgroup)
12.1 micro
seconds
FC/FICON only on a 2.5-Gbps aggregated signal mixed with GE
on the same 10-Gbps ITU trunk card (single port in portgroup)
12.8 micro
seconds
15.2 micro
seconds
23.9 micro
seconds
FC/FICON only on a 2.5-Gbps aggregated signal mixed with GE
on the same 10-Gbps ITU trunk card (two ports in portgroup)
13.5 micro
seconds
16.8 micro
seconds
26.2 micro
seconds
Table A-15 2-Gbps FC and FICON Latency Values for 4-Port 1-Gbps/2-Gbps Aggregation Cards
Traffic Mix on Transmitting Node
Maximum Added End-to-End Latency
No GE
1518-Byte
GE Packets
4470-Byte
GE Packets
10,232-Byte
GE Packets
FC/FICON only on the 2.5-Gbps aggregated signal carried over
a 2.5-Gbps ITU trunk card
10.6 µs
FC/FICON only on a 2.5-Gbps aggregated signal carried over a
10-Gbps ITU trunk card
9.9 µs
FC/FICON only on a 2.5-Gbps aggregated signal mixed with GE
on the same 10-Gbps ITU trunk card
12.1 µs 15.4 µs 25.1 µs