Datasheet

Table Of Contents
A-11
Cisco ONS 15454 SDH Reference Manual, R7.0
October 2008
Appendix A Hardware Specifications
A.4.3 XC-VXL-10G Card Specifications
Synchronization
Stratum 3, per ITU-T G.812
Free running access: Accuracy +/– 4.6 ppm
Holdover stability: 3.7 * 10 exp – 7 per day including temperature (< 255 slips in first 24 hours)
Reference: External BITS, line, internal
Supply voltage monitoring
Both supply voltage inputs are monitored
Normal operation:
–40.5 to –56.7 V (in –48 VDC systems)
–50.0 to –72.0 V (in –60 VDC systems)
Undervoltage: Major alarm
Overvoltage: Major alarm
Environmental
Operating temperature: –40 to +55 degrees Celsius (–40 to +149 degrees Fahrenheit)
Operating humidity: 5 to 95 percent, noncondensing
Power consumption: 26.00 W, 0.54 A at –48 V, 0.43 A at –60 V, 88.8 BTU/hr
Dimensions
Height: 321.3 mm (12.650 in.)
Width: 18.2 mm (0.716 in.)
Depth: 228.6 mm (9.000 in.)
Depth with backplane connector: 235 mm (9.250 in.)
Weight (not including clam shell): 0.7 kg (1.5 lb)
A.4.3 XC-VXL-10G Card Specifications
The XC-VXL-10G card has the following specifications:
Environmental
Operating temperature: –5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit)
Operating humidity: 5 to 85 percent, noncondensing
Power consumption: 81.30 W, 1.69 A at –48 V, 277.6 BTU/hr
Dimensions
Height: 321.3 mm (12.650 in.)
Width: 18.2 mm (0.716 in.)
Depth: 228.6 mm (9.000 in.)
Depth with backplane connector: 235 mm (9.250 in.)
Weight (not including clam shell): 0.6 kg (1.5 lb)