Specifications

4-81
Cisco ONS 15454 Troubleshooting and Maintenance Guide
November 2001
Chapter 4 Card Reference
OC48 LR/STM16 LH AS 1550 Card
4.26.1 OC48 LR/STM16 LH AS 1550 Card-Level Indicators
The OC48 LR/STM16 LH AS 1550 card has three card-level LED indicators.
4.26.2 OC48 LR/STM16 LH AS 1550 Port-Level Indicators
You can find the status of the OC48 LR/STM16 LH AS 1550 card port using the LCD screen on the ONS
15454 fan-tray assembly. Use the LCD to view the status of any port or card slot; the screen displays the
number and severity of alarms for a given port or slot. See Chapter 1, Alarm Troubleshooting for a
complete description of the alarm messages.
Warning
Invisible laser radiation may be emitted from the end of the unterminated fiber cable or connector.
Do not stare into the beam or view directly with optical instruments. Viewing the laser output with
certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a
distance of 100 mm may pose an eye hazard. Use of controls or adjustments or performance of
procedures other than those specified may result in hazardous radiation exposure.
4.26.3 OC48 LR/STM16 LH AS 1550 Compatibility
Use the XC10G card, the TCC+ card, the new 15454-SA-ANSI shelf assembly, and Software R3.1 or
higher to enable the OC48 LR/STM16 LH AS 1550 card. The OC48 LR/STM16 LH AS 1550 card uses
the BTC backplane interface to provide recognition in both the high-speed and multispeed slots.
4.26.4 OC48 LR/STM16 LH AS 1550 Card Specifications
Line
Bit Rate: 2.49 Gbps
Code: Scrambled NRZ
Fiber: 1550 nm Single Mode
Loopback Modes: Terminal and Facility
Connectors: SC
Compliance: Telcordia SONET, GR-GSY-00253, ITU-T G.707, ITU-T G.957
Table 4-37 OC48 LR/STM16 LH AS 1550 Card-Level Indicators
Card-Level Indicators Description
Red FAIL LED
The red FAIL LED indicates that the cards processor is not ready. Replace
the card if the red FAIL LED persists.
Green ACT LED
The green ACT LED indicates that the OC48 LR/STM16 LH AS 1550 card
is carrying traffic or is traffic-ready.
Amber SF LED
The amber SF LED indicates a signal failure or condition such as LOS, LOF
or high BERs on the cards port. The amber SF LED also illuminates when
the transmit and receive fibers are incorrectly connected. When the fibers are
properly connected, the light turns off.