Specifications

4-52
Cisco ONS 15454 Troubleshooting and Maintenance Guide
November 2001
Chapter 4 Card Reference
DS3-12E Card
Line Code: B3ZS
Termination: Unbalanced coaxial cable
Input Impedance: 75 ohms +/-5%
Cable Loss: Max 450 ft. 734A, RG-59, 728A/Max 79 ft. RG-179
AIS: TR-TSY-000191-compliant
DS3-12E Output
Bit Rate: 44.736 Mbps +/- 20 ppm
Frame Format: DS-3 ANSI T1.107-1988
Line Code: B3ZS
Termination: Unbalanced coaxial cable
Input Impedance: 75 ohms +/-5%
Cable Loss: Max 450 ft. 734A, RG-59, 728A/Max 79 ft. RG-179
AIS: TR-TSY-000191-compliant
Power Level: -1.8 - +5.7 dBm (The power level is for a signal of all ones and is measured at a
center frequency of 22.368 MHz (+/-KHz) bandwidth.)
Pulse Shape: ANSI T1.102-1988 Figure 8
Pulse Amplitude: 0.36 - 0.85 V peak-to-peak
Loopback Modes: Terminal and Facility
Line Build Out: 0-225 ft.; 226-450 ft.
DS3-12E Electrical Interface
Connectors: BNC or SMB
Environmental
Operating Temperature:
I-Temp (15454-DS3-12E-T): -40 to +65 degrees Celsius
Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card
without this symbol is C-Temp compliant.
Operating Humidity: 5 - 95%, non-condensing
Power Consumption: 26.80 W, 0.56 amps, 91.51 BTU/Hr.
Dimensions
Height: 12.650 in., Width: 0.716 in., Depth: 9.000 in.
Depth with backplane connector: 9.250 in.
Card Weight: 1.8 lbs, 0.8 kg
Compliance
ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950,
CSA C22.2 No. 950, EN 60950, IEC 60950