Specifications

4-22
Cisco ONS 15454 Troubleshooting and Maintenance Guide
November 2001
Chapter 4 Card Reference
XC Cross-Connect Card
4.7.2 XC Specifications
Cross-Connect
Connection Setup Time: 5 ms
Latency: 270 ns
Environmental
Operating Temperature:
C-Temp (15454-XC): 0 to +55 degrees Celsius
I-Temp (15454-XC-T): -40 to +65 degrees Celsius
Note The I-Temp symbol is displayed on the faceplate of an I-Temp compliant card. A card
without this symbol is C-Temp compliant.
Operating Humidity: 5 - 95%, non-condensing
Power Consumption: 13 W, 0.28 amps, 46 BTU/Hr.
Dimensions
Height: 12.650 in.
Width: 0.716 in.
Depth: 9.000 in.
Card Weight: 1.5 lbs, 0.7 kg
Compliance
ONS 15454 cards, when installed in a system, comply with these standards: Safety: UL 1950,
CSA C22.2 No. 950, EN 60950, IEC 60950