Specifications
3-31
Cisco ONS 15454 Troubleshooting and Maintenance Guide
November 2001
Chapter 3 Maintenance
Electrical Interface Assembly Replacement
3.14 Electrical Interface Assembly Replacement
Electrical interface assemblies (EIAs) provide cable connection points on the back of the ONS 15454
and come in several configurations that work with different cards and connections (see Table 3-1). For
more information about EIAs, see the “Installation” chapter of the Cisco ONS 15454 Installation and
Operations Guide.
EIAs have two sides. As you face the rear of the ONS 15454 shelf assembly, the right-hand side is the
A side and the left-hand side is the B side. You can install EIAs on one or both sides of the ONS 15454
backplane in any combination. For example, you can use an AMP Champ EIA on side A and a BNC EIA
on side B. The top of the EIA connector columns are labelled with the corresponding slot number, and
EIA connector pairs are marked Tx and Rx to correspond to transmit and receive cables. EIAs come
pre-installed on the ONS 15454 when ordered with the node.
3.14.1 EIA Types
Table 3-1 gives the product numbers and common names for EIAs.
Table 3-1 EIA Configurations
EIA Type
Cards
Supported
A Side
Hosts
A Side
Columns
Map to A Side Product Number
B Side
Hosts
B Side
Columns
Map to B Side Product Number
BNC DS-3
DS3XM-6
EC-1
24 pairs of
BNC
connectors
Slot 2
Slot 4 15454-EIA-BNC-A24
24 pairs of
BNC
connectors
Slot 14
Slot 16 15454-EIA-BNC-B24
High-
Density
BNC
DS-3
DS3XM-6
EC-1
48 pairs of
BNC
connectors
Slot 1
Slot 2
Slot 4
Slot 5
15454-EIA-BNC-A48
48 pairs of
BNC
connectors
Slot 13
Slot 14
Slot 16
Slot 17
15454-EIA-BNC-B48
SMB DS-1
DS-3
EC-1
DS3XM-6
84 pairs of
SMB
connectors
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
15454-EIA-SMB-A84
84 pairs of
SMB
connectors
Slot 12
Slot 13
Slot 14
Slot 15
Slot 16
Slot 17
15454-EIA-SMB-B84
AMP
Champ
DS-1 6 AMP
Champ
connectors
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
15454-EIA-AMP-A84
6 AMP
Champ
connectors
Slot 12
Slot 13
Slot 14
Slot 15
Slot 16
Slot 17
15454-EIA-AMP-B84