Specifications

3-7
Cisco ONS 15454 Troubleshooting and Maintenance Guide
November 2001
Chapter 3 Maintenance
Alarm Interface Panel Replacement
Figure 3-4 Removing or replacing the fan-tray assembly
3.3 Alarm Interface Panel Replacement
If the alarm interface panel (AIP) fails, a MAC Fail alarm displays on the CTC Alarms menu and/or the
LCD display on the fan tray will go blank.
Note A blown fuse on the AIP board can cause the LCD display to go blank.
To return a failed AIP, you must follow the standard Return Material Authorizations (RMA) procedures;
call (800) 553-NETS (6387) if you do not have an RMA number. Call Cisco Technical Assistance Center
(TAC) at 877-323-7368 for assistance in replacing the AIP and maintaining the original MAC address.
For more information on the AIP, see Chapter 1 in the Cisco ONS 15454 Installations and Operations
Guide.
Caution Do not perform this procedure on a node with live traffic. Hot-swapping the alarm interface panel
(AIP) can affect traffic and result in a loss of data. For assistance with AIP replacement contact Cisco
Technical Assistance Center (TAC) at 877-323-7368.
F
A
N
F
A
IL
C
R
IT
M
A
J
M
IN
Fan tray
assembly
38532