Specifications

CHAPTER
3-1
Cisco ONS 15454 Troubleshooting and Maintenance Guide
November 2001
3
Maintenance
This chapter describes maintenance information and procedures for Cisco ONS 15454, including:
Air filter inspection and replacement
Fan-tray assembly replacement
Alarm interface panel replacement
System reset
Database backup and restore
Reverting to an earlier software load
Card replacement
TCC card to TCC+ card upgrade
XC card to XCVT card upgrade
XC/XCVT card to XC10G card upgrade
DS3/DS3N card to DS3E/DS3EN card upgrade
Span upgrades
Protection group switching
Electrical interface assembly (EIA) replacement
Fiber cleaning
Powering down a node
3.1 Air Filter Inspection and Replacement
The ONS 15454 contains an air filter that you should remove and visually inspect approximately every
30 days, depending on the cleanliness of the operating environment. NEBS 3E and later versions of the
ONS 15454 use a reusable air filter that is installed either beneath the fan-tray assembly or in the
optional external filter brackets. Earlier versions of the ONS 15454 use a disposable air filter that is
installed beneath the fan-tray assembly only. For more information about filter brackets and air filter
installation, see the Installation chapter of the Cisco ONS 15454 Installation and Operations Guide.
Warning
Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed
circuitry could constitute an energy hazard.