Chapter 1 Alarm Troubleshooting
1.3.95 PRC-DUPID
• Major, Service affecting
The PRC-DUPID alarm indicates that two identical node IDs exist in the same ring. The ONS 15454
requires each node in the ring to have a unique node ID.
Procedure: Clear the PRC-DUPID Alarm on an OC-N Card in a BLSR
Step 1 Find the nodes with identical node IDs.
a. Log into a node on the ring.
b. Click the Provisioning > Ring tabs.
c. Record the Node ID number.
d. Repeat steps a – c for all nodes in the ring.
Step 2 If two nodes have an identical node ID number, change the node ID number of one node.
a. Log into a node that has an identical node ID number.
b. Click the Provisioning > Ring tabs.
c. Change the number in the Node ID field to a unique number between 0 and 31.
d. Click Apply.
1.3.96 PWRRESTART
• Not Alarmed (NA) (Condition)
A Power Fail Restart is a cold boot of the reporting card. This alarm can occur when you physically
remove and insert a card, power up an ONS 15454, or replace a card.
Caution Always use the supplied electrostatic discharge wristband when working with a powered ONS 15454.
Plug the wristband cable into the ESD jack located on the lower-right outside edge of the shelf
assembly.
Procedure: Clear the PWRRESTART Condition
Step 1 If the alarm fails to clear after the card reboots, physically reseat the card.
Step 2 If the alarm still fails to clear, replace the card.
Note When you replace a card with an identical type of card, you do not need to make any changes
to the database.