Datasheet

Data Sheet
© 2008 Cisco Systems, Inc. All rights reserved. This document is Cisco Public Information. Page 9 of 25
Environmental alarm contacts
4-alarm output contact closures (standard): critical, major, minor, remote
Up to 48 provisionable alarm contacts in systems equipped with Alarm Interface
Controller (AIC-I)
Network Security Features
Four-level user control with provisionable timeout durations: super-user, provisioning,
maintenance, retrieve
Multiple user names and logged-in users
RADIUS based authentication
Maintenance Features
Remote software downloads and in-service, hitless activation
Loopbacks
Database backup and restore
Lamp test
Timing and Synchronization
Two external timing-source inputs (SONET, T1 and SDH E-1, 2 MHz)
Line timing
Two timing-source outputs
Internal Stratum 3
Synchronous status-messaging support
Additional Features
100-Mbps user data channel (Fast Ethernet) transported on the optical supervisory channel
(OSC)
Front only (ETSI) or front and rear access (ANSI) shelf assembly options
A and B fully redundant and monitored DC power inputs
Carrier-Class Availability
Delivers better then 99,999% availability
All cards hot-swappable
Fully redundant Network Element processor and database
Compliance and Certifications
Network Equipment Building Standards (NEBS) Level 3 compliance
ITU-T and CE Mark compliance
Operations Systems Modification of Intelligent Network Elements (OSMINE) certifications
Storage-vendor qualification and certifications
MEF 9 and MEF 14 certification for GE and 10GE Xponder units