Troubleshooting guide
11
Release Notes for Cisco ONS 15454 Release 7.0.2
OL-11368-01
Caveats
CSCeh43011
An LOS alarm is cleared when switching to protect when the working card is on opposite side of the
shelf from the protect card (in portless configuration) in a DS3XM-12 1:N protection group. An
electrical port brought into IS state on the portless only card produces an LOS alarm. If you then switch
to protect, the alarm appears to clear. To avoid this issue, do not bring electrical ports into IS state on a
portless only card. This issue will be resolved in a future release.
CSCdx40300
A transient WKSWPR condition is raised upon deletion of a DS3XM 1:1 protection group. This issue
will be resolved in a future release.
CSCec39567
Deleting a DS3I 1:N protection group may leave the protect card LED in a standby state. This can occur
in a DS3I 1:N protection group with a LOCKON applied to the working card (ONS 15454 ANSI chassis
only). Upon deleting the protection group, the LED on the protect DS3I card and the CTC display are
still in the standby state. Soft reset the protect card to update the LED on the card and in CTC. An
alternative workaround is to remove the LOCKON before deleting the protection group. This issue will
be resolved in a future release.
Data IO Cards
SONET and SDH Card Compatibility
Tables 1, 2, and 3 list the cards that are compatible for the ONS 15454 SONET and ONS 15454 SDH
platforms. All other cards are platform specific.
Table 1 SDH Data Cards that are SONET Compatible
Product Name Description
15454E-G1000-4 4 port Gigabit Ethernet Module - need GBICs
15454E-E100T-12 12 port 10/100BT Ethernet Module
15454E-E1000-2 2 port Gigabit Ethernet Module - need GBICs
15454E-ML100T-12 10/100 Mbps Ethernet card, 12 ports, RJ-45,
L2/L3 switching, SDH/ETSI system, includes
console cable
15454E-ML1000-2 1000 Mbps Ethernet card, 2 SFP slots, L2/L3
switching, SDH/ETSI system