Technical data
TraverseEdge 2020 Applications and Engineering Guide, Chapter 3: System Applications
Release 5.0.x Turin Networks Page 3-13
Equipment Requirements
Table 3-5 shows module and shelf requirements for the TE-2020 Main Shelf configured as a 1+1 terminal
node with 16 protected OC-12 drops. Refer to the following documents for more information:
• For physical layer module part numbers and availability, refer to the TE-2020 Ordering Guide
(WR-D2020-ORD-050000).
• For detailed physical descriptions of the modules, refer to the TE-2020 Hardware Description
Guide (WR-D2020-HWD-050000).
3.2.4 OC-192 1+1 Terminal with Optical and DS3/EC-1 Tributaries
Figure 3-14 shows additional diversity of the TE-2020 system. It is deployed using OC-192 interfaces,
eight optical tributary cards, and 48 DS3/EC-1 drops. This configuration requires only seven rack units of
space.
Table 3-5 OC-192 Terminal with 16 Protected OC-12 Drops Equipment Requirements
QTY Part
1 TE-2020 Main Shelf
2 TE-2020 Main CCT
1 TE-2020 Main Fan Tray
2 OC-192 x1 PLM
1OTS2
2 OTS2 CCT
1OTS2 Fan Tray
2 Local Equipment Interconnect Cable Pair
8 OC-12 x4 PLM