Technical data

TraverseEdge 2020 Applications and Engineering Guide, Chapter 2: System Features
Release 5.0.x Turin Networks Page 2-5
Front Ethernet Port
Rear DB-9 RS-232 User Port
Dual rear Ethernet connections
Dual external synchronization BITS source inputs
Dual derived DS1 external synchronization clock outputs
DTAU Feature (added in Release 5.0 see 2.5 DTAU Feature)
Up to four protected LEIs (Local Equipment Interconnection) to trib shelves
Single port OC-192 PLM
Single port ITU widely tunable 88 channel OC-192 PLM
Four Port OC-48 PLM
Dual Port OC-48 PLM
Single port OC-48 PLM
Single Port OC-48 SFP Base PLM (IR-1, LR-1, LR-2 & DWDM SFPs)
Dual port OC-12 PLM
Quad port OC-12 PLM
Quad port OC-3 PLM
Dual port GbE PLM
Dual port Enhanced GbE PLM
12 port DS3/EC-1 PLM (per port configurable as DS3 or EC-1) with test access
12 port DS3 Transmux PLM with test access
Up to 192 DS3/EC-1 interfaces (1:n [n = 1-4] card level protection)
12 Port FastE PLM
28 Port and 84 Port DS1 PLMs with test access
Housekeeping alarm inputs (16) /outputs (2)
2 Critical, 2 Major, and 2 Minor visual/audible outputs
Alarm cut-off
Operational
On-board power conversion from -48Vdc source
-5 to 55 degree Celsius operational temperature range (0° to 40° C for ITU Grid PLMs)
Hot-swappable field replacable units
Compliance
FCC Part 15 Class B
UL 60950 (Third Edition) also covers CSA (C22.2 Nos. 950 - M 95)
CDRH Laser Certification (21 CFR 1040.10)
NEBS Level 3 Certification
ANSI 2136.1