Technical data

TraverseEdge 2020 Applications and Engineering Guide, Chapter 11: Interoperability
Release 5.0.x Turin Networks Page 11-3
Node ID (Range1-16) on each OSIRIS ring network that it is connected to. DCC wrapping and recovery
from fiber failures is fully implemented (
TE-2020 is a full participant in the OSIRIS DCC).
NOTE: Only a single
TE-2020 is currently supported per OSIRIS ring. OSIRIS Node numbers are
of local significance with an OSIRIS only. A single
TE-2020 may use the same OSIRIS Node num-
ber on every OSIRIS ring it is connected to if required.
11.1.3 OC3/OC12 URSR Ring Support
Currently supported on only TE-2020 Main Shelf
- Full STS1 cross-connect between MAS/OSIRIS rings
- Support for Max 8 OC3/OC12 UPSR rings
Path Switching Support:
- STS1 Path Switching
- VT1.5 Path Switching
NOTE: Contact Turin Networks Marketing for further information on configurations supported.
Hardware and Software Requirements
At least one OSIRIS node in each ring managed must be equipped with an NMCU CPU card
(remainder can have MCU CPU cards).
NOTE: NMCU = OSIRIS CPU with integrated LAN management port. MCU = OSIRIS CPU with-
out a LAN management port.
OSIRIS Software Requirements
Software Version 5.9.4/5.99.4 for NMCU based OSIRIS NEs
Software Version 3.99.2/3.9.2 for MCU based OSIRIS-NEs
IP Address Allocation Requirements
One IP address required per TE-2020 plus one IP subnet per managed OSIRIS ring
OSIRIS to TE-2020 Fiber Connectivity
Since OSIRIS NEs have an OC-3 or OC-12 OAU (Optical Access Unit) per UPSR path while the TE-2020
has an Optical PLM per direction (e/w), each TE-2020 optical PLM must have fiber connections to both
OSIRIS OAUs.
NOTE: The OSIRIS DCC has two logical directions (termed DCC-X and DCC-Y). In order for the
OSIRIS DCC to function correctly, the X-DCC on one NE must be connected to Y-DCC on the next
in order for the DCC to operate correctly and to survive fiber failures. Figure 12-6 indicates the cor-
rect fiber layout from a
TE-2020 to an OSIRIS as follows:
NOTE: The leftmost OAU card slot in an OSIRIS system is designated OAU-A while the rightmost
OAU slot is designated OAU-B
Xmt of OC-3/12 PLM in top TE-2020 CCT connects to OAU B Rcv on OSIRIS