Table 7-17 Calculated Link Distances for Corning MetroCor
Module Name Dispersion
(ps/nm)
Dispersion
Parameter
(ps/nm-km)
Dispersion
Limit (km)
Ptmin
(dBm)
Prmin
(dBm)
Attenuation
(dB/km)
Loss
Limit
(km)
Total Reach
(km)
OC-192 ITU
LR
1
1600 7.0 228.5 +4 -24 0.22 86.3 86.3 (loss)
OC-192 LR-2 1600 7.0 228.5 -2 -26 0.22 95.4 95.4 (loss)
OC-192 IR-2 800 7.0 114.2 -1 -14 0.22 45.4 45.4 (loss)
OC-192 SR-1 500 24.0 20.8 -6 -11 0.4 5 5 (loss)
OC-48 ITU 1600 7.0 228.5 +5 -28 0.23 91.3 91.3 (loss)
OC-48 LR-2 1600 7.0 228.5 -2 -28 0.23 100 100 (loss)
OC-48 VR-1 1200 24.0 50.0 +3 -28 0.42 66.67 50 (disp)
OC-48 LR-1 1200 24.0 50.0 -2 -28 0.42 54.76 50 (disp)
OC-48 IR-1 800 24.0 33.3 -5 -18 0.44 22.73 22.7 (loss)
OC-12 LR-1 92 24.0 3.8 -3 -28 0.42 52.38 3.8 (disp)
OC-12 IR-1 46 24.0 1.9 -15 -28 0.41 24.39 1.9 (disp)
OC-3 LR-1 246 24.0 10.2 -5 -34 0.43 60.47 10.2 (disp)
OC-3 IR-1 96 24.0 4.0 -15 -28 0.435 22.99 4 (disp)
Table 7-18 Calculated Link Distances for Lucent AllWave
Module Name Dispersion
(ps/nm)
Dispersion
Parameter
(ps/nm-km)
Dispersion
Limit
(km)
Ptmin
(dBm)
Prmin
(dBm)
Attenuation
(dB/km)
Loss
Limit
(km)
Total Reach
(km)
OC-192 ITU
LR
1
1600 18.0 88.8 +4 -24 0.25 76 76 (loss)
OC-192 LR-2 1600 19.0 84.2 -2 -26 0.25 84 84 (loss)
OC-192 IR-2 800 18.0 44.4 -1 -14 0.25 40 40 (loss)
OC-192 SR-1 500 1.5 333.3 -6 -11 0.5 4 4 (loss)
OC-48 ITU 1600 18.0 88.8 +5 -28 0.25 84 84 (loss)
OC-48 LR-2 1600 19.0 84.2 -2 -28 0.25 92.22 84.2 (disp)
OC-48 VR-1 1200 1.5 800.0 +3 -28 0.45 62.22 62.2 (loss)