Technical data
TraverseEdge 2020 Applications and Engineering Guide, Chapter 7: Optical Link Design
Page 7-16 Turin Networks Release 5.0.x
OC-48 LR-2 1600 18.0 88.8 -2 -28 0.25 92.00 88.8 (disp)
OC-48 VR-1 1200 1.5 800.0 +3 -28 0.45 62.22 62.2 (loss)
OC-48 LR-1 1200 1.5 800.0 -2 -28 0.45 51.11 51.1 (loss)
OC-48 IR-1 800 1.5 533.3 -5 -18 0.45 22.22 22.2 (loss)
OC-12 LR-1 92 1.5 61.3 -3 -28 0.45 48.89 48.8 (loss)
OC-12 IR-1 46 1.5 30.6 -15 -28 0.45 22.22 22.2 (loss)
OC-3 LR-1 246 1.5 164.0 -5 -34 0.45 57.78 57.7 (loss)
OC-3 IR-1 96 1.5 64.0 -15 -28 0.45 22.22 22.2 (loss)
Table 7-16 Calculated Link Distances for Corning SMF-28 ™
Module Name Dispersion
(ps/nm)
Dispersion
Parameter
(ps/nm-km)
Dispersion
Limit (km)
Ptmin
(dBm)
Prmin
(dBm)
Attenuation
(dB/km)
Loss
Limit
(km)
Total Reach
(km)