Technical data
TraverseEdge 2020 Applications and Engineering Guide, Chapter 7: Optical Link Design
Release 5.0.x Turin Networks Page 7-3
7.1.3 OC-48 PLMs
The current OC-48 PLM offerings include a single-, two-, and four-port versions. There is an IR-1
reach PLM and five types of long reach (LR-1, LR-2, VR-1, and ITU) modules that may be uti-
lized according to wavelength and power desired. Refer to Table 7-3 and Table 7-4 for OC-48
PLM specifications.
P
O
1 1 dB
Receiver Reflectance (max) -27 -14 dB
Connector Type MPO MPO
Table 7-3 OC-48 IR Optical Parameters
Parameter IR-1 Unit
Transmitter SLM
λ
Tmin
-λ
Tmax
1266-1360 nm
∆λ
rms(max)
NA nm
∆λ
20(max)
1 nm
SSR
min
30 dB
P
Tmax
0 dBm
P
Tmin
-5 dBm
r
e(min)
8.2 db
Optical Path
System ORL
min
24 dB
D
SR(max)
NA ps/nm
Attenuation 0-13 dB
Max. Reflectance between S and R -27 dB
Receiver
P
Rmax
0 dBm
P
Rmin
-18 dBm
P
O
1 dB
Receiver Reflectance (max) -27 dB
Table 7-2 OC-12 Laser Specifications
Parameter IR-1 LR-1 Unit