5.8 Optical PLM Power Requirements
OTS2 Enhanced Main CCT 75 Watts
OTS2 Main CCT w/2.5G VT Fabric 81
OTS2 Main CCT w/5G VT Fabric 86.25
ETS1 CCT 25 Watts
ETS2 CCT 25 Watts
Table 5-4. Optical PLM Power Requirements
PLM Power Consumption
OC-192 x1 SR 1310 37 Watts
OC-192 x1 IR 1550 39 Watts
OC-192 x1 LR2 1550 45 Watts
OC-192 x1 ITU 47 Watts
OC-48 x1 IR 1310 12 Watts
OC-48 x1 LR1 1310 13.6 Watts
OC-48 x1 LR2 1550 13.6 Watts
OC-48 x1 VR-1 1310 13.6 Watts
OC-48 x1 SFP Base 15.4 Watts
OC-48 x2 IR 1310 22 Watts
OC-48 x2 LR1 1310 22 Watts
OC-48 x4 (IR, LR, LR2) 37 Watts
OC-12 x2 IR 9.1 Watts
OC-12 x2 LR 1310nm 11 Watts
OC-12 x4 IR 1310 13.5 Watts
OC-12 x4 LR 1310nm 16 Watts
OC-3 x4 IR 1310nm 8.2 Watts
OC-3 x4 LR 1310nm 13 Watts
1000Base-SX x2 MMF 850 17 Watts
1000Base-LX x2 SMF 1310 18 Watts
1000Base-ZX x2 SMF 1550 19 Watts
1000Base-SX x2 MMF 850 Enhanced 15 Watts
Table 5-3. CCT Power Requirements
Shelf Power Consumption