Technical data

TraverseEdge 2020 Applications and Engineering Guide, Chapter 5: Electrical Interface Specifications
Page 5-6 Turin Networks Release 5.0.x
A simplified diagram is shown in Figure 5-1 that shows how the external interface might be utilized.
Table 5-9 Pinout for Audible Alarm Pins
Connector Name Connector
Number
Pin
Number
In/Out Max
Current
Max
Voltage
Critical Audible Out () J6 10 Out 30 mA - 60 Vdc
Critical Audible In (+) J6 9 In 30 mA Return / GND
Major Audible Out () J7 10 Out 30 mA - 60 Vdc
Major Audible In (+) J7 9 In 30 mA Return / GND
Minor Audible Out () J8 10 Out 30 mA - 60 Vdc
Minor Audible In (+) J8 9 In 30 mA Return / GND
Table 5-10 Alarm Cut-off (ACO) Pins
Connector Name Connector
Number
Pin
Number
In/Out Max
Current
ACO In J5 9 In 83 mA
ACO Out J5 10 Out 83 mA