Chapter 6 Troubleshooting
Troubleshooting Commands
Troubleshooting Commands
Use the following troubleshooting commands to review alarms and the overall status of the ONS 15216
EDFA1 and, if necessary, to reprovision the amplifier.
For additional detailed information regarding each of the following commands, see Chapter 5,
“Command Line Reference.”
STAT Command
You can view the following information using the STAT command:
• Amplifier mode of operation
• Individual pump laser statistics
• Electrical statistics
• Environmental statistics
• Input and output optical signals level
• Amplifier gain
As seen in the following example, you can use this information to quickly isolate any possible problem
with the ONS 15216 EDFA1.
Example 6-1 STAT Command Results
0-0>STAT 1
LD 1: Const Pump Crnt 10(mA) <<< Ctrl-X to Stop >>>
LD 2: Const Pump Crnt 10(mA)
LD T/To TEC LDPwr LDCrnt Amb DC In Out Gain
(C) (mA) (mW) (mA) (C) (V) (uW/dBm) (mW/dBm) (dBm)
1 25.5/25.5 39 0.49 9.92 30.25 5.2 0.0/-120.00 0.00/-90.00 30.0
Alarm Display/Clear Commands
Use the ALARM D command to view active ONS 15216 EDFA1 alarms. These alarms are also helpful
in determining the location and type of problem with the ONS 15216 EDFA1.
See the “ALARM” section on page 5-6 for additional information about this command.
Example 6-2 Alarm D Command
0-0>ALARM D
Pump 1 Pump 2
Name Type Crnt Cnt Crnt Cnt Descr
LCRNT Minor xxxxx yyy xxxxx yyy Excessive pump crnt/pump bias
LTMP Minor xxxxx yyy xxxxx yyy LD temp out-of-range
EDFA 1
Name Type Crnt Cnt Descr
LPOUT Major xxxxx yyy Loss outp pwr
LPIN Major xxxxx yyy Loss inp pwr
GAIN Major xxxxx yyy Gain out-of-range