Specifications

5-27
Cisco ONS 15216 EDFA Operation Guide
78-12818-01
Chapter 5 Command Line Reference
Command Summary
INACTIMER
<minutes>
Inactivity Command This command sets the
inactivity timeout. If no
keyboard activity is detected
during this timeout, the EDFA
automatically logs out.
(Minutes = 1 to 255)
LD Laser Status Display This command displays the
control mode of each laser
diode pump..
LOAD Start | Abort |
Report
Firmware Download
to EDFA
This command initializes the
module to accept remote
downloads of new firmware.
LOGOUT Logout Command This command logs out of the
current unit. The command will
return to the current prompt and
then terminate the command
line interface serial session with
the EDFA.
PASS <password.>
[<new password>]
Password This command enables
password-protected commands
and can change passwords.
PRM 1|2 Parameter Display This command enables the
parameters for pumps one and
two.
SETADDR xx (where
xx is a decimal
number)
Sets address of
EDFA
This command assigns a
two-digit address value (range 0
to 99) to an EDFA.
!SETADDR xx
(where xx is a decimal
number)
Bootstraps the EDFA
address
An exclamation point placed at
the beginning of the
SETADDR command
overrides the EDFA's logon
requirement. This allows a new
address to be assigned without
knowledge of the EDFA's
current address.
After the confirmation prompt
is returned, the user is logged
out.
SET_LOSTH [D]
<value,-15 to -31
dBm>]
Set, get, or disable
the loss of signal
threshold
This command performs three
functions: set and enable the
loss-of-input signal threshold,
get the current loss-of-input
signal threshold, or disable the
loss-of-input signal alarm.
Table 5-17 Command Summary (continued)
Command Syntax Function Description