Specifications

5-21
Cisco ONS 15216 EDFA Operation Guide
78-12818-01
Chapter 5 Command Line Reference
Maintenance Commands
Maintenance Commands
The following are maintenance commands.
CUTOVER
Explanation:
After a new firmware version is downloaded to the EDFA's inactive plane, the CUTOVER command
begins executing the new firmware. The cutover process is similar to a cold restart, except that
information about control loops is stored and recovered after booting so that the EDFA can resume
control where it left off. Alarm reporting can be incorrect during a cutover. Cutoveris approximately 12
seconds.
If any unsaved configuration parameters are present when the cutover command is issued, a prompt
appears that permits you to save the modified parameters. All unsaved modified parameters will be lost
during the cutover process.
Table 5-12 Laser Diode Pump Parameters
Parameter Format Description
n 1 or 2 Laser diode pump number
xxx 0..100 Set laser diode pump power in mW
Command: CUTOVER
Syntax: CUTOVER
Password: Yes
Configuration: Yes
Brief
Description:
Executes firmware from the inactive plane and changes
inactive plane status to the default active plane